Insulation voltage

 

 

Rated insulation voltage Ui 

500 V~ 

Rated impulse  withstand voltage Uimp 

6.5 kV 

Operating frequency withstand voltage 

3.5 kV 

Ambient conditions  

 

Operating temperature  

-30 - +70°C 

Storage temperature 

-30 - +80°C 

Relative humidity 

80% (IEC/EN 60068-2-78) 

Maximum degree of ambient pollution 

Overvoltage category  

Measurement category  

III 

Climate sequence 

Z/ABDM (IEC/EN 60068-2-61) 

Shock resistance 

15 g (IEC/EN 60068-2-27) 

Vibration resistance 

0.7 g (IEC/EN 60068-2-6) 

Connections 

 

Terminal types 

Extractable 

Cable cross section (min. & max.) 

0.2-2.5 mmq  (24

12 AWG) 

UL use data 
Cable cross section (min. & max.) 

0.75 - 2.5 mm² (18-12 AWG) 

Tightening torque 

0.56 Nm (5 Lbin) 

Enclosure 

 

Version 

Flat panel mounted 

Material 

Polycarbonate 

Front protection rating 

RGK400SA 

 

RGK420SA 

IP20 at terminals 
IP40 at front panel 
IP65 at front panel with optional gasket 
IP40 at front panel 

Weight 

400 g 

Type-approvals and conformity 

Type-approvals  

cULus pending, EAC pending 

Conformity to standards 

IEC/EN 61010-1, IEC/EN 61010-2-030, IEC/EN 61326-1 
UL508 and CSA C22.2-N°14 

UL Marking 

Use 60°C/75°C copper (CU) conductor only 
AWG Range: 18 - 12 AWG stranded or solid 
Field Wiring Terminals Tightening Torque: 4.5 lb.in 
Flat panel mounting on a Type 1 or 4X enclosure 
(RGK400SA only) 

 
 
 

Manual revision history

 

 

 

 
 
 
 
 
 
 

Rev Date 

Notes 

00 21/05/2016  First 

revision 

 

Содержание RGK400SA

Страница 1: ...s 3 Navigating between the display pages 3 Switching on and starting up RGK400SA 3 Switching on and starting up RGK420SA 3 Expandability 4 Inputs and outputs 4 User alarms UAx 4 IR programming port 4...

Страница 2: ...eter and alarm messages in 5 languages ENG ITA FRA SPA DEU 3 Ph N 480 VAC rated generator voltage measuring input 1 ph current input 6 digital inputs including o 4 standard digital inputs o 1 digital...

Страница 3: ...er only switches off at the end of this after the engine has stopped During the cooling cycle the display reads out a countdown of the time to engine shutdown If you wish to stop the engine immediatel...

Страница 4: ...occurs o the properties of the alarm as for standard alarms i e how it interacts with the genset controller If the alarm is displayed following activation of an external digital input then the source...

Страница 5: ...f the RGK4 SA controller more or less in the position shown alongside Hold it in position for a few seconds until you hear a beep The app runs automatically and the parameters are loaded and displayed...

Страница 6: ...or voltage parameters P13 GENERATOR PROTECTION Alternator protection functions P14 DIGITAL INPUTS Programmable digital input functions P15 DIGITAL OUTPUTS Programmable digital output functions P17 MIS...

Страница 7: ...ment P04 n 01 Rated generator voltage Always set phase to phase voltage for polyphase systems P04 n 02 Choice of connection type three phase with without neutral two phase or single phase P04 n 03 Vol...

Страница 8: ...asurements while performing calibration P08 04 Selection of unit of measure for oil pressure P08 05 P08 06 The minimum oil pressure pre alarm and alarm thresholds respectively See the corresponding al...

Страница 9: ...C P11 03 Generator frequency threshold for determining motor running P11 04 W speed or pick up signal threshold or AC from permanent magnet alternator threshold for determining motor running P11 05 Gl...

Страница 10: ...ed current for alarm A31 Maximum generator current P13 02 Delay for alarm in previous parameter P13 03 Percentage threshold referred to rated current for alarm A32 Generator short circuit P13 04 Delay...

Страница 11: ...of the signal the engine begins its stop cycle Start without stop Starts the engine remotely and does not stop it in the event of an alarm The signal must be maintained for as long as the engine needs...

Страница 12: ...time set in P05 04 A16 Battery voltage low Occurs if battery voltage remains below the threshold set in P05 03 for longer than the time set in P05 04 A17 Battery discharged Occurs if engine start atte...

Страница 13: ...Manual circuit breaker open A46 Cannot change configuration A47 Water in fuel UA1 UA1 UA2 UA2 A38 System error 5V Occurs if an internal error occurs in the RGK4 SA controller Contact Technical Support...

Страница 14: ...e sensor offset Advanced Calibrates resistive sensors by adding subtracting a value in Ohms to the resistance measured by them to compensate for cable length or resistance offsets Calibration is made...

Страница 15: ...K ALIMENTATO 18 12 11 13 14 L3 L1 L2 L3 24 L1 25 L2 23 S1 21 20 S2 RGK420SA 3 4 5 17 6 N N 22 19 10 9 8 F F4A ELETTROV CARBURANTE FUEL SOLENOID VALVE START AVVIAMENTO F F6A LIVELLO CARBURANTE AN MASSA...

Страница 16: ...OIL PRESSURE T1A 15 16 3 4 5 17 6 LIBERO 1 2 FREE F INP5 INP6 INP4 INP3 INP2 INP1 ARRESTO DI EMERGENZA ALTERNATORI TIPO BOSCH MARELLI LUCAS PICK UP PICK UP BATTERY ALTERNATOR TYPE BOSCH MARELLI LUCAS...

Страница 17: ...4 23 22 21 19 16 18 15 BATTERY 20 17 8 10 12 14 7 9 11 13 2 4 6 1 3 5 L1 L2 L3 N S1 S2 COM1 OUT2 OUT4 COM2 D OUT1 OUT3 OUT5 INP1 AN INP3 INP5 S GND INP2 INP4 100 500VLL 50 60Hz CAT III I 0 025 5A SSR...

Страница 18: ...impedance 100 K Pre excited battery charging alternator 500 rpm input terminal 7 Operating range 0 33 V Max input current 1 mA Max voltage at D terminal 12 or 24 VDC battery voltage Excitation curren...

Страница 19: ...max 0 2 2 5 mmq 24 12 AWG UL use data Cable cross section min max 0 75 2 5 mm 18 12 AWG Tightening torque 0 56 Nm 5 Lbin Enclosure Version Flat panel mounted Material Polycarbonate Front protection ra...

Отзывы: