M2375 

Ingresso PLC 02 

PLC input 02 

  

  

M2376 

Ingresso PLC 03 

PLC input 03 

  

  

M2377 

Ingresso PLC 04 

PLC input 04 

  

  

M2378 

Ingresso PLC 05 

PLC input 05 

  

  

M2379 

Ingresso PLC 06 

PLC input 06 

  

  

M2380 

Ingresso PLC 07 

PLC input 07 

  

  

M2381 

Ingresso PLC 08 

PLC input 08 

  

  

M2410 

Uscita PLC 01 

PLC output 01 

  

  

M2411 

Uscita PLC 02 

PLC output 02 

  

  

M2412 

Uscita PLC 03 

PLC output 03 

  

  

M2413 

Uscita PLC 04 

PLC output 04 

  

  

M2414 

Uscita PLC 05 

PLC output 05 

  

  

M2415 

Uscita PLC 06 

PLC output 06 

  

  

M2416 

Uscita PLC 07 

PLC output 07 

  

  

M2417 

Uscita PLC 08 

PLC output 08 

581 

I/O - 1s - 2 giorni 

I/O - 1s - 2 days 

M1701 

Data register 21 2 dec 

Data register 21 2 dec 

  

  

M1702 

Data register 22 2 dec 

Data register 22 2 dec 

  

  

M2374 

Ingresso PLC 01 

PLC input 01 

  

  

M2375 

Ingresso PLC 02 

PLC input 02 

  

  

M2376 

Ingresso PLC 03 

PLC input 03 

  

  

M2377 

Ingresso PLC 04 

PLC input 04 

  

  

M2378 

Ingresso PLC 05 

PLC input 05 

  

  

M2379 

Ingresso PLC 06 

PLC input 06 

  

  

M2380 

Ingresso PLC 07 

PLC input 07 

  

  

M2381 

Ingresso PLC 08 

PLC input 08 

  

  

M2410 

Uscita PLC 01 

PLC output 01 

  

  

M2411 

Uscita PLC 02 

PLC output 02 

  

  

M2412 

Uscita PLC 03 

PLC output 03 

  

  

M2413 

Uscita PLC 04 

PLC output 04 

  

  

M2414 

Uscita PLC 05 

PLC output 05 

  

  

M2415 

Uscita PLC 06 

PLC output 06 

  

  

M2416 

Uscita PLC 07 

PLC output 07 

  

  

M2417 

Uscita PLC 08 

PLC output 08 

680 

Campionamento 5s generico  Generic 5s sampling time 

M1 

Tensione Di Fase L1 

L1 Phase Voltage 

M2 

Tensione Di Fase L2 

L2 Phase Voltage 

M3 

Tensione Di Fase L3 

L3 Phase Voltage 

 

M5 

Tensione L1-L2 

L1-L2 Voltage 

 

M6 

Tensione L2-L3 

L2-L3 Voltage 

 

M7 

Corrente Di Fase L1 

L1 Current 

 

M8 

Corrente Di Fase L2 

L2 Current 

 

M9 

Corrente Di Fase L3 

L3 Current 

 

M10 

Tensione L3-L1 

L3-L1 Voltage 

 

M20 

Potenza Attiva L1 

L1 Active Power 

 

M21 

Potenza Attiva L2 

L2 Active Power 

 

M22 

Potenza Attiva L3 

L3 Active Power 

 

M23 

Potenza Reattiva L1 

L1 Reactive Power 

 

M24 

Potenza Reattiva L2 

L2 Reactive Power 

 

M25 

Potenza Reattiva L3 

L3 Reactive Power 

681 

Campionamento 5s correnti 

Current 5s sampling time 

M7 

Corrente Di Fase L1 

L1 Current 

M8 

Corrente Di Fase L2 

L2 Current 

Содержание EXCCGLA01

Страница 1: ...GATEWAY DATA LOGGER MODEM 2G 3G Operating manual Manuale operativo EXCGLA01 EXCGLAX1 I600IGB03_19 31100438...

Страница 2: ...r EXCGLA01 in grado di raccogliere dati dai dispositivi in campo collegati tramite porta ethernet o seriale RS485 anche contemporaneamente Supporta i protocolli Modbus RTU ASCII e TCP I dati possono e...

Страница 3: ...rnet e seriale RS485 per un totale massimo consentito di 31 unit Connections EXCGLA01 should be connected to a 24VDC power supply The devices in the field can be connected to both the ethernet and the...

Страница 4: ...zo seriale nodo Si possono assegnare valori compresi tra quelli impostati nella sezione Canali vedere pi avanti Sulla porta ethernet il gateway data logger apre un servizio sulla porta 1000 che quindi...

Страница 5: ...PS abilitato di fabbrica per l accesso all interfaccia web EXCGLA01 dotato di un certificato di protezione con firma automatica Quindi collegandosi viene visualizzato un messaggio di sicurezza Accetta...

Страница 6: ...ation is possible for some of the models only ant it can take several minutes Mostra i data log in cui il dispositivo contenuto Goes to the data logs which the device is included in Modifica la defini...

Страница 7: ...Data logs are data tables with timestamp information The data tables are defined in EXCGLA01 database and become automatically available according to the model of the device which has been recognized...

Страница 8: ...basato Shows the data log which the chart is based on Canali I due canali fisici di comunicazione seriale RS485 e ethernet verso i dispositivi in campo sono descritti da alcuni parametri che possono e...

Страница 9: ...azione System Some system information is shown i e memory availability No setup is required Data Ora Si accede a questo menu per modificare la data e l ora di riferimento per EXCGLA01 Queste informazi...

Страница 10: ...bbrica admin Indirizzo server remoto l end point a cui inviare il file XML dei dati raccolti Nome utente e password credenziali per autenticarsi presso il server remoto all atto dell invio file Admini...

Страница 11: ...ente pu scegliere La selezione viene fatta automaticamente da EXCGLA01 nel caso per il dispositivo aggiunto sia disponibile una sola scelta altrimenti l utente chiamato a indicare il gruppo di interes...

Страница 12: ...GSM900 8 PSK Class E2 26dBm 3dB per DCS1800 e PCS1900 8 PSK Class 3 24dBm 1 7 3 7dB per UMTS 800 850 900 1900 21 Technical characteristics EXCGLA01 System resources CPU ARM Cortex A8 1 GHz Operating s...

Страница 13: ...ETSI EN 301 489 1 ETSI EN 301 489 52 EN 301 511 ETSI EN 301 908 1 ETSI EN 301 908 2 EN 62311 EN 60950 1 Interface Antenna GSM UMTS antenna 50 SMA F Female connector SIM slot microSIM Environmental co...

Страница 14: ...transfer switch 139 300 65 DCRG8 DCRG8F Rifasamento PFC 136 900 400 135 300 65 DMG DME PMVF Base Basic 568 60 10 569 300 35 571 86400 1500 570 900 400 DMG PMVF Base EXP EXM Basic EXP EXM 568 60 10 569...

Страница 15: ...3_19 docx DISPOSITIVI DEVICES DESCRIZIONE DESCRIPTION DATA LOG TEMPO DI CAMPIONAMENTO SAMPLING TIME s GIORNI DI MEMORIA DAYS OF MEMORY DME CD Base Basic 578 900 400 579 86400 1500 LRD Base Basic 580 5...

Страница 16: ...N M2015 Tensione L3 L1 GEN L3 L1 Voltage GEN M2054 Potenza attiva Equivalente GEN Eqv Active Power GEN 133 Motore Engine M2016 Tensione batteria Bettery voltage M2083 Ore di lavoro totali Total workin...

Страница 17: ...in 10 days M7 Corrente Di Fase L1 L1 Current M8 Corrente Di Fase L2 L2 Current M9 Corrente Di Fase L3 L3 Current M11 Tensione Di Linea Equivalente Eqv Phase To Phase Voltage M13 Potenza Reattiva Equiv...

Страница 18: ...ars M911 Ingresso Analogico 1 Analog Input 1 M912 Ingresso Analogico 2 Analog Input 2 575 Misure 15min 1 anno Measures 15min 1 year M901 Energia Attiva Importata L1 L1 Active Energy Import M906 Energi...

Страница 19: ...ente L1 12 Harmonic L1 Current M242 12 Armonica Corrente L2 12 Harmonic L2 Current M243 12 Armonica Corrente L3 12 Harmonic L3 Current M244 13 Armonica Corrente L1 13 Harmonic L1 Current M245 13 Armon...

Страница 20: ...M2378 Ingresso PLC 05 PLC input 05 M2379 Ingresso PLC 06 PLC input 06 M2380 Ingresso PLC 07 PLC input 07 M2381 Ingresso PLC 08 PLC input 08 M2410 Uscita PLC 01 PLC output 01 M2411 Uscita PLC 02 PLC ou...

Страница 21: ...Harmonic L1 Current M221 05 Armonica Corrente L2 05 Harmonic L2 Current M222 05 Armonica Corrente L3 05 Harmonic L3 Current M226 07 Armonica Corrente L1 07 Harmonic L1 Current M227 07 Armonica Corrent...

Страница 22: ...mero associato al data log e l indice delle misure sono i riferimenti da utilizzare qualora si volesse elaborare il file XML inviato da EXCGLA01 al server remoto Lo schema XSD disponibile sul sito int...

Отзывы: