Loup Electronics Elite YIELD MONITOR Скачать руководство пользователя страница 4

LOUP ELITE YIELD MONITOR  •  OPERATION MANUAL

4

2.0 main Screen FuncTionS

The following sections will familiarize yourself with the operation 

of the main screen.

2.1 LIvE YIELD

The main readout for yield 

displayed in Bushels/Ac. Live 

yield only displays when 

header is in down position. 

When header is raised the 

Live Yield reads 0.

2.2 HEADER WIDTH REDuCTION

Below the Live Yield is the active sections associated with the 

crop and their status.  The crop sections are defined from the 

Crop Details screen (Section 5.3

If cutting at a partial header width simply select the sections not 

being used to reduce the cut width. If Auto Width Reset is turned 

ON (Section 5.5) for the particular crop, the header will reset to 

full width automatically on the headland turn.

2.3 LIvE TEsT WEIgHT

Displayed just above the Live Yield 

reading, the Live Test Weight is the 

current test weight/Density of the crop 

being harvested. To change the Test Weight simply select this 

icon and use the + or - icons to increase or decrease the current 

test weight.

2.4 REsET LOAD/ADD LOAD

Whats displayed in this 

window depends if Load 

Management is On or Off. By 

default Loads Management 

is off and the The Reset Load window is displayed. This is a 

resettable bushel counter used for the Yield Nudge process.  If 

Load Management is On, the Add Load button will display 

allowing you to accumulate loads or enter the Loads Page. Refer 

to the Yield Nudge process on Section 4.0 for more info.

2.5 CusTOM DIspLAYs 1 AND 2

The two windows right of 

the Reset/Cal load button 

are customizable displays to 

show the information of your choice. Tap each window and from 

the popup window select between Dry Yield, Wet Yield, Dry 

Weight, Wet Weight, Dry Bushels, Wet Bushels, Ave Moisture, 

Field Area, Total Area,Shaft RPM, Grain Loss or Work Rate.

2.5.1 REsETTINg DIspLAYs

A select number of the displays can be reset to 0 while 

harvesting. To reset to 0, press and hold on the desired window 

for 2 seconds and release. From the popup select “Yes, Confirm” 

to reset the value for that window. Resettable items are Wet 

Weight, Wet Bushels, Field Area, and Total Area.

2.6 fIELD AREA

The Field Area will display accumulating acres 

covered for your field. The Field Area can be 

reset by simply selecting it and from the popup 

select “Yes, Confirm” to clear the acres back to 0. 

Resetting the Field Area also resets the Field Average and 

Average % Moisture reading.

Note:  The Field Area is locked when a Task is being logged, 

this to ensure accurate data is recorded to the SD 

memory. Previous Tasks being loaded will resume from 

the last Field Area last recorded.   

2.7 fIELD AvERAgE

The Field Average displays the average 

Bushels/Ac over the duration of a 

logged Task or since the last “Field 

Area” has been reset.

2.8 LIvE MOIsTuRE/AvE. MOIsTuRE

Displays the instant % Moisture reading of the 

crop being harvested. When the header is raised, 

this will switch to the Average Moisture reading. 

The average moisture represents either the 

average of an actively logged Task or since the “Field Area” has 

been reset.

Note: The moisture reading can be locked if needed by long-

pressing on the moisture reading. This long-press will both 

lock or unlock the moisture display.

2.9 COMbINE/spEED

Displays the current Speed (MPH) of the 

combine. Color of the combine will change 

depending on the Combine Make selected 

from the Combine Setup screen.

2.10 fARM/fIELD

If field mapping, use the Farm/Field 

screen to enter the Tasks/Logging screen. 

On this screen you may enter the Task 

name, Farm name and Field name you’d like to log too.

Содержание Elite YIELD MONITOR

Страница 1: ...YIELD MONITOR OPERATION MANUAL...

Страница 2: ...2 LOAD Nudge Load MANAGEMENT ON 7 5 0 Crop DETAILS 8 5 1 Cal number 8 5 2 Standard Density 8 5 3 Header Width 8 5 4 Sections8 5 5 Auto Width Reset 8 5 6 Set the Cutout Height 8 5 7 Moisture Correction...

Страница 3: ...1 Initial FIRST time Setup 1 Select the proper Make Model combine as well as the Header Switch Sensor from the Combine Setup screen Section 6 1 Note If your combine type is set to Other you will need...

Страница 4: ...et Yield Dry Weight Wet Weight Dry Bushels Wet Bushels Ave Moisture Field Area Total Area Shaft RPM Grain Loss or Work Rate 2 5 1 Resetting Displays A select number of the displays can be reset to 0 w...

Страница 5: ...es Below the Task Name you will find the Farm and Field names Selecting the Farm name and or Field name will load the keyboard allowing you to type in a new Farm or Field name 3 3 Crop Variety Below t...

Страница 6: ...ff and this calibration window displays a single resettable Cal Load to be used towards a Yield Nudge When Loads Management is On this window is instead an incrementing load counter with the calibrati...

Страница 7: ...result updates the Cal number associated with that load This Cal number is then also applied to the Active Load to correct the current and all future loads harvested If you wish to apply multiple Loa...

Страница 8: ...5 4 Sections The number of sections defined for each crop will be displayed on the main screen when reducing the header cut width 5 5 Auto Width Reset Set to ON if when cutting at a partial header wi...

Страница 9: ...header switch Select the Type button in the upper left corner to toggle between a Switch and a Sensor type cutout 6 3 1 HEADER PULL Switch Select this option when using a pull chain style cutout swit...

Страница 10: ...t and Front Rear offsets to correct for GPS drift Left Right Offset Negative values represent a Left Offset Positive values represent a Right Offset Front Rear Offset Negative values represent a Front...

Страница 11: ...ifferent levels of grain seen on the elevator paddles A default value for LP0 LP5 will be pre defined based on the Make Model combine used within the Combine Setup page Note While each point can be ma...

Страница 12: ...zero out the angle sensor finish by selecting Exit Save 11 0 Diagnostics The Diagnostics screen can help in identifying issues with sensors harnessing or other items Status reports for Battery Voltag...

Страница 13: ...application to load into the console and when finished cycle power to the console The console will then boot to a black screen and the keypad will pulse while the update completes the install eventua...

Страница 14: ...www loupelectronics com 1 877 489 5687...