Loup Electronics Elite YIELD MONITOR Скачать руководство пользователя страница 10

LOUP ELITE YIELD MONITOR  •  OPERATION MANUAL

10

6.4.3 WHEEL puLsEs pER 400fT 

This value directly affects the MPH reading 

when a shaft sensor is used. Perform a Speed 

Calibration to properly calibrate the sensor to 

your combine. This number may be changed by selecting it and 

entering a new value from the numpad. 

6.4.4 spEED CALIbRATION

To calibrate the proper Pulses Per 400ft, first 

measure off 400ft. Select “Start Calibration” 

and drive the 400ft distance. Wheel pulses 

received will begin to accumulate, press “Stop Calibration” and 

select “Exit & Save” to complete the calibration. 

6.5 gRAIN LOss

If you have an optional grain loss sensor, 

toggle this option to “ON”. When enabled, 

use the “Set Zero” button to zero the sensor.

7.0 gpS SeTTingS

7.1 gps bAuDRATE

From the popup select the appropriate 

baudrate for your GPS receiver (4800, 9600, 

19200, 38400, or 115200).

7.2 gps OffsETs

On rare occasion a GPS receiver may drift 

from the center point of the header. Use the 

Left/Right and Front/Rear offsets to correct 

for GPS drift. 

Left/Right Offset:  Negative (-) values represent a Left Offset. 

Positive (+) values represent a Right Offset.

Front/Rear Offset:  Negative (-) values represent a Front Offset. 

Positive (+) values represent a Rear Offset.

7.3 gps spEED CORRECTION

If on rare occasion the GPS speed is 

incorrect, use this option to apply a Positive 

or Negative speed correction.

7.4 gps sTATus

Use this page to confirm communication to 

your GPS receiver. Information for current 

Latitude, Longitude, Number of connected 

Satellites, GPS Messages, and GPS Fix Quality are displayed.

8.0 yield SenSor SeTTingS

8.1 sET TARE

Setting the Tare of your combine’s clean grain 

elevator should only need to be done once. 

Run the elevator at maximum speed while 

empty. Once at full speed select the “Set Tare” button, note the 

“Elevator Zero, and “Actual” values should now match in value.

Elevator Zero = The currently set zero/tare value of the elevator

Actual = Live elevator reading. Under normal operating 

conditions this value should be equal to the zero or above the 

zero when harvesting.

Frequency = Displayed in Hz, this represents the Paddles per 

Second rate of the elevator.

Содержание Elite YIELD MONITOR

Страница 1: ...YIELD MONITOR OPERATION MANUAL...

Страница 2: ...2 LOAD Nudge Load MANAGEMENT ON 7 5 0 Crop DETAILS 8 5 1 Cal number 8 5 2 Standard Density 8 5 3 Header Width 8 5 4 Sections8 5 5 Auto Width Reset 8 5 6 Set the Cutout Height 8 5 7 Moisture Correction...

Страница 3: ...1 Initial FIRST time Setup 1 Select the proper Make Model combine as well as the Header Switch Sensor from the Combine Setup screen Section 6 1 Note If your combine type is set to Other you will need...

Страница 4: ...et Yield Dry Weight Wet Weight Dry Bushels Wet Bushels Ave Moisture Field Area Total Area Shaft RPM Grain Loss or Work Rate 2 5 1 Resetting Displays A select number of the displays can be reset to 0 w...

Страница 5: ...es Below the Task Name you will find the Farm and Field names Selecting the Farm name and or Field name will load the keyboard allowing you to type in a new Farm or Field name 3 3 Crop Variety Below t...

Страница 6: ...ff and this calibration window displays a single resettable Cal Load to be used towards a Yield Nudge When Loads Management is On this window is instead an incrementing load counter with the calibrati...

Страница 7: ...result updates the Cal number associated with that load This Cal number is then also applied to the Active Load to correct the current and all future loads harvested If you wish to apply multiple Loa...

Страница 8: ...5 4 Sections The number of sections defined for each crop will be displayed on the main screen when reducing the header cut width 5 5 Auto Width Reset Set to ON if when cutting at a partial header wi...

Страница 9: ...header switch Select the Type button in the upper left corner to toggle between a Switch and a Sensor type cutout 6 3 1 HEADER PULL Switch Select this option when using a pull chain style cutout swit...

Страница 10: ...t and Front Rear offsets to correct for GPS drift Left Right Offset Negative values represent a Left Offset Positive values represent a Right Offset Front Rear Offset Negative values represent a Front...

Страница 11: ...ifferent levels of grain seen on the elevator paddles A default value for LP0 LP5 will be pre defined based on the Make Model combine used within the Combine Setup page Note While each point can be ma...

Страница 12: ...zero out the angle sensor finish by selecting Exit Save 11 0 Diagnostics The Diagnostics screen can help in identifying issues with sensors harnessing or other items Status reports for Battery Voltag...

Страница 13: ...application to load into the console and when finished cycle power to the console The console will then boot to a black screen and the keypad will pulse while the update completes the install eventua...

Страница 14: ...www loupelectronics com 1 877 489 5687...