Loup Electronics Elite YIELD MONITOR Скачать руководство пользователя страница 11

LOUP ELECTRONICS  •  1-877-489-5687  •  WWW.LOUPELECTRONICS.COM

11

8.2 YIELD sMOOTHINg 

(Default: 4, Range 1-10) - The Yield 

Smoothing represents the window of time 

used in calculating yield information. Setting 

to a higher value such as 9 seconds would increase how much 

yield data is factored and as a result the Live Yield readout would 

change more gradually between higher and lower yielding areas.

8.3 YIELD DELAY 

(Range 1-20 seconds) - The Yield Delay 

represents the amount of time grain takes 

to travel from the combine header up to the 

yield sensor location in the clean grain elevator. 

8.4 LOAD MANAgEMENT

By default Load Management is turned off 

on Loup Elite. When load management is 

on, the main screen is changed to allow for 

an accumulating number of loads. Individual Load nudges can 

also be performed from the Loads Page. See Section 4.2 for more 

information. 

9.0 advanced yield SeTTingS

The Advanced Yield Settings screen is used to modify the 

individual Line Points (LP) of each crop or redefine each line 

point through the Auto Calibration mode.

9.1 LINE pOINTs

Each crop has its own set of Line Points, 

these points represent different levels of 

grain seen on the elevator paddles. A default 

value for LP0 - LP5 will be pre-defined based on the Make & 

Model combine used within the Combine Setup page. 

Note:  While each point can be manually changed, its not 

recommended to do so. Contact Loup Electronics for 

futher assistance.

9.2 AuTO CAL

Using the Auto Calibration is a method of 

redefining the LP1 - LP5 points for the crop 

selected. 

Note:  The default LP points are typically appropriate under 

most applications and as a result the Auto Cal is not a 

required procedure. 

If yield inconsistencies appear even after performing the standard 

calibration process, performing an Auto Cal is recommended.

9.2.1 AuTO CAL pROCEDuRE

Prior to starting the Auto Cal process, have available a portion of 

crop to harvest that’s relatively uniform. 

Upon entering the Auto Cal screen, note the readings for Yield 

DelayMPHGrain %, and which crop the Auto Cal is set too. 

There are 5 stages to performing an auto calibration; Max speed, 

¾ speed, ½ speed, ¼ speed, and ⅛ speed. The Elite console will 

guide you through each stage and display the speed you should 

travel on each.

Max Speed: To start the monitor will instruct you to harvest at 

maximum speed. When up to your Max Speed, select the “Set 

Cal” button to move on to the next stage (Note the Grain % is 

recorded into the first box for “Max Speed”). 

Содержание Elite YIELD MONITOR

Страница 1: ...YIELD MONITOR OPERATION MANUAL...

Страница 2: ...2 LOAD Nudge Load MANAGEMENT ON 7 5 0 Crop DETAILS 8 5 1 Cal number 8 5 2 Standard Density 8 5 3 Header Width 8 5 4 Sections8 5 5 Auto Width Reset 8 5 6 Set the Cutout Height 8 5 7 Moisture Correction...

Страница 3: ...1 Initial FIRST time Setup 1 Select the proper Make Model combine as well as the Header Switch Sensor from the Combine Setup screen Section 6 1 Note If your combine type is set to Other you will need...

Страница 4: ...et Yield Dry Weight Wet Weight Dry Bushels Wet Bushels Ave Moisture Field Area Total Area Shaft RPM Grain Loss or Work Rate 2 5 1 Resetting Displays A select number of the displays can be reset to 0 w...

Страница 5: ...es Below the Task Name you will find the Farm and Field names Selecting the Farm name and or Field name will load the keyboard allowing you to type in a new Farm or Field name 3 3 Crop Variety Below t...

Страница 6: ...ff and this calibration window displays a single resettable Cal Load to be used towards a Yield Nudge When Loads Management is On this window is instead an incrementing load counter with the calibrati...

Страница 7: ...result updates the Cal number associated with that load This Cal number is then also applied to the Active Load to correct the current and all future loads harvested If you wish to apply multiple Loa...

Страница 8: ...5 4 Sections The number of sections defined for each crop will be displayed on the main screen when reducing the header cut width 5 5 Auto Width Reset Set to ON if when cutting at a partial header wi...

Страница 9: ...header switch Select the Type button in the upper left corner to toggle between a Switch and a Sensor type cutout 6 3 1 HEADER PULL Switch Select this option when using a pull chain style cutout swit...

Страница 10: ...t and Front Rear offsets to correct for GPS drift Left Right Offset Negative values represent a Left Offset Positive values represent a Right Offset Front Rear Offset Negative values represent a Front...

Страница 11: ...ifferent levels of grain seen on the elevator paddles A default value for LP0 LP5 will be pre defined based on the Make Model combine used within the Combine Setup page Note While each point can be ma...

Страница 12: ...zero out the angle sensor finish by selecting Exit Save 11 0 Diagnostics The Diagnostics screen can help in identifying issues with sensors harnessing or other items Status reports for Battery Voltag...

Страница 13: ...application to load into the console and when finished cycle power to the console The console will then boot to a black screen and the keypad will pulse while the update completes the install eventua...

Страница 14: ...www loupelectronics com 1 877 489 5687...