OUTPUT CABLE CONNECTION
Make sure copper screw of another end of torch is connected to gas-electrical
integration terminal then tighten them clockwise relation (prevent from leaking
gas).
Connect the ground cable to the positive terminal of front panel then tighten it.
Note: The receptacle is keyed. Align the key on the work lead connector with the opening
at the top of the receptacle on the power supply.
Push the work lead connector all the way into the receptacle on the power supply and
turn clockwise, approximately 1/4 turn, until the connector is fully seated against the stop
in order to achieve an optimal electrical connection.
Caution: Ensure the work lead is fully seated in the receptacle
to prevent overheating.
CHECK
Check if cutting machine is grounded reliably according to standard.
Check if all connectors are connected firmly.
Check if power voltage is correct.
NOTE THE FOLLOWING
Ensure that the work clamp and the work piece make good metal-to-metal
contact. Remove rust, dirt, paint, coatings and other debris to ensure the power
supply makes proper contact with the work piece.
For the best cut quality, attach the work clamp as close as possible to the area
being cut.
Do not attach the work clamp to the portion of the work piece which will be cut
away.