 03.87.76.32.51 - Email: [email protected] - [email protected]

 

 
FIRMWARE update 

To access to the firmware update function, you must first open an HyperTerminal session on a PC, connect the device 
to the PC with the RS232 link cable and then power on the device.  
 
The following character is send to the terminal: 
 

>

 

<

————————

 The device sends this character then it waits the « F » key during 0.5 s. 

 
 
If the user has pressed the « F » key in the allowed time, the following message is displayed in the HyperTerminal win-
dows: 
 
 

FIRMWARE LOADER Rev0 
READY TO TRANSFER... 

 
 
The device is now in file waiting mode. This file is provide by LOREME. This file contain the firmware code in intel HEX 
format. Selected the « Transfer », « Send a text file ... » in the HyperTerminal menu. 
Select the directory and open the file. The HyperTerminal program begins to send the file to the device.  
 
 

FIRMWARE LOADER Rev0 
READY TO TRANSFER 
*********** 

<

————————

 The star characters appears to show the progress of the uploading. 

 
 
At the end, the message « 

PROGRAMMING OK ! 

» is display if no errors occurs. Otherwise, these following message 

could be displayed: 
 
 

SERIAL COM ERROR ! 

Error during receipt. 

 

- SERIAL TIMEOUT ! 

 

Waiting time of receipt elapsed. 

 

PROGRAMMING FAILED ! 

  Programming error in the internal flash memory. 

 
 
 
Attention: 

If an error occurs during the programming process, it is necessary to start again the whole procedure.  
A bad programming leads to incorrect or bad operation of the device. 

Содержание THL105

Страница 1: ...S AND RIBBONS LOREME 12 rue des Potiers d Etain Actipole BORNY B P 35014 57071 METZ CEDEX 3 Phone 03 87 76 32 51 Contact Commercial Loreme fr Technique Loreme fr Download manual at www loreme fr CONFI...

Страница 2: ...RATION p3 1 Hysteresis configuration p4 2 Delay configuration p4 3 End of configuration p4 RS232 LINK SETTING p5 TERMINAL MODE p6 Visualization p6 Configuration p6 1 Method p6 2 Configurable parameter...

Страница 3: ...etpoint The button allows you to increment the setpoint and the button to decrement it The setpoint is incremented or decremented in steps of 1 C at the beginning Holding pressed the or button for mor...

Страница 4: ...e Config button to validate the setting 0 to 50 C 2 Delay configuration RETARD Press the or button to increment or decrement the delay value 0 1 s steps 0s Press the Config button to validate the sett...

Страница 5: ...ates another communication port number COMx and re quires the reconfiguration of the HyperTerminal The terminal emulation software for PC HyperTerminal is resident in windows up to XP version For late...

Страница 6: ...modification by typing Enter The modification with simultaneous display followed by validation with Enter key 2 Configurable parameters The following parameters can be configured The threshold setpoin...

Страница 7: ...s 100 5 C Temperature value with offset OFFSET 0 5 offset function temperature offset value Use keys and to adjust offset the temperature is directly modified Type on Enter to save the new offset OFFS...

Страница 8: ...waiting mode This file is provide by LOREME This file contain the firmware code in intel HEX format Selected the Transfer Send a text file in the HyperTerminal menu Select the directory and open the...

Страница 9: ...n fifty centimeters of a device with a transmitter walkie talkie of a power of 5 W be cause the latter can create a field with an intensity higher than 10 V M for a distance fewer than 50 cm 2 2 Power...

Страница 10: ...Loreme fr Technique Loreme fr Wirings PC DEVICE LINK DIAGRAMS OF CONNECTIONS 3 terminals plug to THL105 LINK in FRONT FACE under the cover Female 9 terminals to PC 3 5 2 Cover lift here PT100 sensor P...

Отзывы: