3DM-GX4
™
-45
™
Inertial Navigation System
User Manual
Performance Optimization
36
Figure 24 -
Collect Calibration Data
5. When all possible rotations are completed, select Stop Collecting and then select
Save Data to save the calibration data points (
Figure 25 - End Calibration
).
Figure 25 -
End Calibration
6. Select the Spherical Fit or Ellipsoid Fit button, depending on the application.
Spherical Fit is often the best fit for applications with calibration rotations restricted to
a 2D plane. For example, a ground vehicle or a boat because it will not likely not be
rotated on all three axis. Ellipsoid Fit is generally a better correction when soft iron
effects are present, but only if enough data points can be collected in all quadrants. If
the range of motion is restricted in one dimension, the Spherical Fit may be the best