Common Functions
Gas test
- press key A14
- the gas test LED is lit
- the solenoid valve is switched on for 30 seconds
-
press key A14 again to switch off the valve manually
Fan test
When switching on the machine at the on/off switch, the fans are activated for a short time during initialisation.
Water pump test
Basic/BasicPlus:
-
press key A2 and keep it pressed for about 5 seconds (menu machine configuration)
- select menu item “CoL” with the left encoder
- with the setting “on” the water pump runs continously
- with the setting “Aut” the water cooling runs in automatic mode (factory setting)
ControlPro:
- select menu item M4 Settings
- select Menu item M4-3 Mode cooling unit
- selection “On” the water pump is running continously
- selection “Auto” the water pump runs in automatic mode (factory setting)
-
press knob A49 to confirm the new selection
Front panel test
- press keys A2 and A14 at the same time
- all LEDs are on
Master reset
Basic/BasicPlus:
-
switch off the machine
- press key A2 and keep it pressed
- switch on the machine with the key pressed
- release key A2
- select parameter “rSt” with the left encoder
- press key “Save”
ControlPro:
-
switch off the machine
- press and hold menu key A50
- switch on the machine with the key pressed
- release menu key A50
- selec parameter “Masterreset” with knob A49
-
press knob A49 to confirm
Since software version 2.02, the start-menu can also be accessed without switching off the machine:
- press and hold the keys A2 and A32
- after about 3 seconds the start-menu is displayed
- select “rSt” (BasicPlus) or “Masterreset” (ControlPro)
-
press key A14 “Save” (BasicPlus) or press knob A49 (ControlPro) to confirm