Heating Specifications 

Approximate Maximum Heating Capacity (in square feet)* ............................................ Up  to  2,000 Sq. Feet 
BTUs Per Hour ............................................................................................................... 13,940 to 49,200 ** 
Burn Rate (Pounds per Hour)*** .................................................................................... 1.7 to 6 
Maximum Burn Time on Low Burn*** ............................................................................. 47  Hours 
Hopper Capacity ............................................................................................................ 80 Pounds 
Turn-Down Ratio ............................................................................................................ 72% 

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature.  It is 
also affected by the fuel size, quality, and moisture level. 

** 

Based on 8,200 BTUs per pound. 

***  Small pellet size will decrease the stated burn rates and burn times.  Differences of plus or minus 20% depending on 

fuel quality may occur. 

Dimensions 

 

Electrical Specifications 

Electrical Rating ...................................................................................................... 115 Volts, 4 Amps, 60 Hz 
Watts during Start-Up Sequence ............................................................................ 480 (approximately) 
Watts during Operation ........................................................................................... 300  (approximately) 

Fuel 

This heater is designed and approved for pelletized wood fuel only (all grades). 

Emissions 

This heater meets the 2015 U.S. EPA’s pelletized wood emission limits for pellet heaters sold after May 
15, 2015. Tested to Method 28, 5G2 this heater has been shown to deliver heat at rates ranging from 
12,100 to 41,100 BTU/hr and an emission value of 0.73g/h.

 

Efficiency 

This model was not tested for efficiency however it is assigned a default efficiency of 78% by the EPA 
under previous subpart AAA. 

 

3" (77mm) Dia. Exhaust 
(centered on appliance)

3" (77mm) Dia. Air Intake

5" (127mm)

25-1/2" (648mm)

26-1/2"
(674mm)

36"

(915mm)

45-1/2"

(1156mm)

Centerline of Air 
Intake and Exhaust

WEIGHT: 340 lbs. (154 Kg)

9" (229mm)

Содержание Foxfire AGP

Страница 1: ...structions could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Save these inst...

Страница 2: ...installation and operation of your new heater an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heate...

Страница 3: ...6 Setting the Target Temperature 26 Internal Built In Thermostat 26 External Thermostat 26 To Start the Stove in Thermostat Mode 26 To Adjust the Heat Output 26 To Shut Down 26 Thermostat Programs 27...

Страница 4: ...clearances or within the space required for charging and ash removal Do not unplug the heater if you suspect a malfunction Press the STOP button and periodically inspect the heater Do not alter this a...

Страница 5: ...e The heater will not operate during a power outage This heater must be connected to a standard115 V 60 Hz grounded electrical outlet Do not use an adapter plug or sever the grounding plug Do not rout...

Страница 6: ...aust venting system The exhaust venting system should be inspected at least twice every year to determine if cleaning is necessary NEVER USE SUBSTITUTE MATERIALS FOR ANY PURPOSE ON THIS APPLIANCE Esta...

Страница 7: ...y may occur Dimensions Electrical Specifications Electrical Rating 115 Volts 4 Amps 60 Hz Watts during Start Up Sequence 480 approximately Watts during Operation 300 approximately Fuel This heater is...

Страница 8: ...icials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation Packing List Installation Options Residential or Mobile Hom...

Страница 9: ...an swing within e g drapes doors 36 915mm of the front of the heater If the stove is placed in a location where the ceiling height is less than 7 2 134 M it must follow the requirements in the section...

Страница 10: ...g on the brand of pellet vent used To determine the distance from the backwall to the stove connect the Tee and add the vent clearance The floor protection must extend 2 51mm beyond the pipe all vent...

Страница 11: ...elbows one tee with two 90 elbows one tee with one 90 and two 45 elbows etc Maximum Venting Distance Vent must have a support bracket every 5 1 524 M of pellet vent when on exterior of structure NOTE...

Страница 12: ...the side of the house Must not be located where it will become plugged by snow or other material A Minimum 4 1220mm clearance below or beside any door or window that opens This clearance may be reduc...

Страница 13: ...awl space HINT Travis Industries strongly recommends outside air for all residential installations especially for those that are energy efficient air tight homes or when using vent without rise Must n...

Страница 14: ...helps prevent the burn platform from over filling with pellets and becoming clogged with ash clumps Keeping your burn platform clean is the most important step to maintaining a safe and efficient hea...

Страница 15: ...dry contact thermostat or remote also called millivolt thermostat remote Use of a voltage producing thermostat 24v 120v AC etc will damage the appliance Connect the leads from the thermostat to the t...

Страница 16: ...rtical vent of 5 to ensure adequate draft during a power outage Install the vent at the clearance specified by the vent manufacturer House Shield used to protect exterior wall from soot discoloration...

Страница 17: ...om a ventilated crawl space 2 Min Vent Clearance 24 Minimum Insulation must maintain clearance 2 Min Ceiling Support Fire Stop Spacer Roof Flashing Storm Collar Vertical Cap Vent must maintain clearan...

Страница 18: ...ass A Chimney Ceiling Support Roof Flashing Use L Vent to Class A Chimney Adapter or Run vent through chimney and use non comustible block off at top of flue Class A Chimney L Vent Storm Collar Class...

Страница 19: ...ove L Vent Flex Section Outside air may be drawn from the ash cleanout L Vent Storm Collar Vertical Cap Cover Plate non combustible Silicone Seal the cover plate with silicone NOTE you may need a shor...

Страница 20: ...rth Stove L Vent Flex Section L Vent Non Combustible Block Off Silicone Seal the block off with silicone and or insulation NOTE you may need a short horizontal section here to clear the lintel and all...

Страница 21: ...allation Example Freestanding Masonry Chimney Install vent at clearance specified by the vent manufacturer 6 Min L Vent Sections L Vent Storm Collar Vertical Cap Cover Plate non combustible Silicone S...

Страница 22: ...HE PELLET VENT UNPLUGGING IT MAY LEAD TO SMOKE ENTERING YOUR ROOM FAILURE TO MAINTAIN YOUR HEATER WILL LEAD TO A RESTRICTED COMBUSTION AIR SYSTEM LEADING TO POOR PERFORMANCE AND IN SOME CASES SMOKE SP...

Страница 23: ...e exhaust blower will run for approx 15 minutes This characteristic is a safety feature used to vacate smoke in case of a power outage Curing the Paint This heater uses a heat activated paint that wil...

Страница 24: ...de Manual Mode requires the user to turn the heater on and off manually and select the heat output setting When in Manual Mode the Thermostat Button will not be lit Thermostat Mode Thermostat T Stat M...

Страница 25: ...op the heater The heater will begin the start up process which can take approximately 20 minutes The On Off Button will transition to GREEN To Shut Down Press the On Off button on the control panel Th...

Страница 26: ...heater wired wireless programmable etc Refer to the instructions included with the external thermostat to set the target temperature To Start the Stove in Thermostat Mode Press the Thermostat Button...

Страница 27: ...thermostat calls for heat thermostat closed Heater runs at setting set on control panel dial If thermostat stops calling for heat thermostat open Heater goes to 3 If after 15 minutes thermostat still...

Страница 28: ...d The fan remains on even at its lowest setting This is used to help cool the internal components and maximize heat transfer Auto Fan Press the Auto Fan Button to activate the auto fan feature This fe...

Страница 29: ...om fan is circulating air When the heater is turned off either manually through a thermostat or a fault occurred the heater moves to the Cool Down phase Cool Down The phase indicates heater has recent...

Страница 30: ...ically done to prevent children or pets from inadvertently adjusting the heater TO LOCK THE STOVE Press the menu button until the Lock Stove menu appears Select the Locked option then WAIT 30 SECONDS...

Страница 31: ...and plugged in This characteristic is a safety feature used to vacate smoke in case of a power outage Manual Mode If a power outage occurs and power is restored while the unit is still hot it will ent...

Страница 32: ...platform Adjust door hinge and latch Check for air leaks Removing Flyash This heater was designed to allow for easy flyash removal with the included tools However to ease maintenance some pellet stov...

Страница 33: ...stove tools may be stored on the hooks on the back of the stove To use the hooks for the first time bend the hooks with a screwdriver or needle nose pliers then hang the tools on the hooks as shown be...

Страница 34: ...ctor position will vary over time as soot builds up inside the exhaust system See Restrictor Adjustment for details Poor pellet quality The door or glass has an air leak The exhaust system requires cl...

Страница 35: ...the pellets to burn completely 4 Brush away flyash around the burn platform using the brush included with the stove The flyash will fall into the ashpan below 5 Remove the wedge that locks the burn p...

Страница 36: ...36 Maintenance Travis Industries 4141007 100 01402 6 Remove the burn platform from the platform holder 7 Clean the inside of the platform holder...

Страница 37: ...before it enters the exhaust blower Remove the liners and clean the area behind them following the directions below 1 Open the door 2 Remove the top liner It is held in place with 3 tabs at the bottom...

Страница 38: ...ris from the firebox Clean the liners before replacing Make sure to clean the heat exchanger on the firebox ceiling Monthly Maintenance or Every 20 Bags of Pellets Clean the Glass Open the doors and c...

Страница 39: ...USE The ashpan will accumulate ash as you use the appliance See the steps below to empty the ashpan 1 Rotate the ashpan handle counter clockwise and swing it out to access the ashpan 2 Slide the ashp...

Страница 40: ...ust Duct 1 Remove the exhaust duct cover as shown below It lifts up and pivots out 2 Remove the exhaust channel cover plate and gasket a single wingnut holds it in place When replaced make sure the ga...

Страница 41: ...s Industries 4141007 100 01402 3 Clean the exhaust channel with the bottle brush or vacuum 4 Clean the combustion blower with the bottle brush or vacuum NOTE Take care to prevent damaging the combusti...

Страница 42: ...ion blowers Starting with the left side panel unscrew the air control rod from the left side and place it aside 2 Each side panel has a thumb screw on the back Remove screw and place it aside 3 Slide...

Страница 43: ...d and cleaned Remove the three screws holding the blower assembly in place see photo below Disconnect the blower assembly the wiring may remain in place during cleaning Clean all dust and debris from...

Страница 44: ...CTED THE JOINTS MUST BE SEALED WITH RTV 500 F SILICONE SEALANT UNLESS OTHERWISE SPECIFIED BY THE VENT MANUFACTURER Check the vent sections for creosote accumulation indicating a poorly burning stove A...

Страница 45: ...seal Bi Yearly Maintenance or Every 2 Tons of Pellets Chisel Inspection Replacement The chisel is used to separate pellets as they drop from the hopper into the feed mechanism The most common symptom...

Страница 46: ...tries designed specifically for this heater Door Parts ID Description Qty Part ID Description Qty Part 1 Glass Gasket 3 8 Diameter 1 250 02801 2 Glass 1 250 02678 3 Glass Clips w Gasket 1 250 00174 4...

Страница 47: ...ush Auger Meter Auger Conv Fan Left White Gray Black Green White Gray Orange Yellow Blue Purple Red Blue 1 2 3 4 5 6 7 8 PINOUTS ARE LOOKING INTO SOCKET SIDE PIN 4 PIN 5 PIN 6 PIN 8 PIN 7 PIN 1 Thermo...

Страница 48: ...e combustion air inlet Part 99200139 or equivalent For use with 1 4 in 6 mm to 5 16 in 7 mm diameter pelletized wood fuels only Replace glass only with 5 mm ceramic glass available from your dealer DA...

Страница 49: ...o the extent of this warranty contact your authorized Travis retailer before installation 5 Travis Industries will not be responsible for inadequate performance caused by environmental conditions such...

Страница 50: ...sed the appliance a copy of your receipt showing the date of the appliance s purchase and the serial number on your appliance At that time you may be asked to ship your appliance freight charges prepa...

Страница 51: ...Limited 7 Year Warranty 51 Travis Industries 4141007 100 01402...

Страница 52: ...nry Chimney 21 Installation Example Interior Vertical Installation 17 Installation Example Masonry Fireplace Hearth Stove 19 Installation Example Zero Clearance Metal Fireplace Hearth Stove 20 Install...

Отзывы: