13
4. Operating the Cryo-Gate
– Press
BACK
to return to the main screen.
– Press
SETTINGS
and at the displayed screen (Fig. 2)
SAVE MANUAL SETTING
,
to get
to the SAVE MANUAL SETTING screen (Fig. 5).
– Select the number of the preset, where you wanted to save the adjusted values and
press
SAVE
.
If you only press
BACK
, you can return to the main screen without saving the values.
b) Using individual values:
– Press
MODIFY
at the main screen. The screen switches to Manual Mode (Fig. 4).
– Adjust the requested values for fog, air and CO
2
, using the
PLUS
or
MINUS
-buttons.
– Press
START ALL
to start all parameters at once, and
STOP ALL
, to stop all parameters.
If you only press
START FOG
, the fogging process will be started, but not air and CO
2
(same for
START AIR
or
START CO2
, whereas START AIR without fog or CO
2
makes
no sense!).
The selected button changes its colour to cyan.
You can return to the main screen, pressing
BACK
.
4.4.2 Operating via analogue
Input voltage between 0 and 10 V. If the voltage is higher than 1 V, the machine will
be controlled via analogue, provided that neither DMX nor Ethernet is active.
To adjust the analogue in, press the
ANALOG
-Button
at the main screen (Fig. 1, line 1) or press
SETTINGS
and
at the following screen (Fig. 2)
ANALOG
.
Adjoining screen (Fig. 6) displays.
Select one of two modes:
1.
DIRECT
(line 2) for e. g. Look XLR-remote:
One Preset is active for an input voltage between 1
and 5 V, a second one for 5 to 9 V.
1 - 5 V correspond to the first half of the rotary knob
at the XLR-remote, 5 - 9 V to the second half.
– Select
1-5V PRESET
and adjust the requested preset
with
PLUS
and
MINUS
(line 4). Then switch to
5-9V
PRESET
and select this one as well.
2.
LATCHED
(line 3): Switching the preset on and off with a short voltage impulse e.g.
with a push-button or a radio remote.
– Select the requested preset with
PLUS
and
MINUS
(line 4).
Fig. 6 Select Analog Mode