LRF-3000H Handheld Ultrasonic Flowmeter
- 24 -
items. Once the “Other” is selected, the relevant
liner sound velocity must be entered in Window
M17.
Menu
1
7
Liner Sound Velocity
Enter liner sound velocity. It only can be visited
when item “ Other” in Window M16 is selected.
Menu
1
8
Liner Thickness
Enter liner thickness. It only can be visited when a
definite liner is selected in Window M16.
Menu
2
0
Select Fluid Type
The following options are available:
0.
Water
1.
Sea Water
2.
Kerosene
3.
Gasoline
4.
Fuel Oil
5.
Crude Oil
6.
Propane
7.
Butane (0◦C)
8.
Other
9.
Diesel Oil
10.
Castor Oil
11.
Peanut Oil
12.
Gasoline #90
13.
Gasoline #93
14.
Alcohol
15.
Water (125◦C)
Menu
2
1
Fluid Sound Velocity
Enter the fluid sound velocity. It only can be used
when item “Other” is selected in window M20, i.e.
it is unnecessary to enter all the fluids listed in
Window M20.
Menu
2
2
Fluid Viscosity
Enter fluid’s kinematics viscosity. It only can be
used when item “Other” is selected in Window
M20, i.e. it is unnecessary to enter all the fluids
that listed in Window M20.
Menu
17
Liner Sound
Velocity
1328m/s
14
:
55
:
15
Q
=
97
R
Menu
18
Liner Thickness
2
14
:
55
:
28
Q
=
97
R
Menu
20
Fluid Type
0.
Water
14
:
55
:
58
Q
=
97
R
Menu
21
Fluid Sound
Velocity
1428.9m/s
14
:
56
:
00
Q
=
97
R