LONGHORN LHD8003 Скачать руководство пользователя страница 6

Figure -2-

3.3 GSM Module

It  enables  the  system  to  support  GSM  or  SMS  alarm.  SIM  card  must  be  inserted  with  both AC  and  DC 

Figure -3-

4.1 Pre-installation Planning

Before  starting  the  installation  procedure,  it  is  worthwhile  to  draw  a  rough  sketch  of  the  building  and 

determine  the  required  position  for  the  control  panel  and  each  wireless  device.  When  deciding  on  the 

placement for installation, consider the following:

1.

 

Mount the control panel in a location with easy access to telephone and power connections.

2 .

 

The control panel should be mounted in a position where the GSM signal is strong.

3.

 

Refer to the following section in order to choose the optimal location for wireless devices in relation  to 

      the control panel.

4.2 W ireless Installation Guidelines

In order to optimize wireless communication, consider the following guidelines:

1.   Whenever possible, mount the panel centrally in relation to wireless sensors.

2.   Avoid installation in close proximity to sources of high noise or radio frequency interference, for

      example, air conditioner, heater or circuit breaker boxes.

3.   Minimize the distance between the panel and transmitters.

4.   Minimize the number of obstacles between the panel and transmitters.

5.   Metal based construction materials, such as steel reinforced concrete walls, will reduce the range of 

      radio transmissions.

Chapter 4: System Installation

3.2  Power Supply Board

It supplies power for main board and GSM module. Pls cut off the power, with both AC and DC power off 

-07-

-08-

Note:  AC power must be connected for normal use. If only with battery, the wired siren can not be driven.

Cable

 

interface

 

for

 

power

connect

 

with

 

power

 

supply

 

board

Flat

-

cable

 

interface

 

for

 

GSM module

Backup

 

battery

 

socket

Socket

 

for

 

power

 

adaptor

GSM

 

module

Flat

-

cable

 

interface

 

for

 

GSM

 

module

SIM

 

card

 

slot

 

Status

 

LED

 

TX

TX

 

obstacles

3   obstacl

es

RX

Figure -4-

Содержание LHD8003

Страница 1: ...86 755 33265388 Website http www csst longhorn com E mail helen p csst com TH ST TH THE 4 BUILDING 1 FLOOR OF THE 5 BUILDING NEW AND HIGH TECHNOLOGY PARK GUANGMING WANDAIHENG BAOAN SHENZHEN CHINA LHD...

Страница 2: ...CREATING SECURITY SOLUTION...

Страница 3: ...Address CMS 2 Phone NO SMS Center 1 SMS Center 1 Address SMS Center 1 Phone NO SMS Center 2 SMS Center 2 Address SMS Center 2 Phone NO 02 PACKING LIST Note It should include screws 4pcs EOL resistanc...

Страница 4: ...1 2 Arm Stay 5 5 6 6 7 7 8 8 8 9 9 10 10 12 13 13 13 14 14 15 15 15 15 16 18 19 19 20 21 22 22 22 23 23 23 24 7 1 3 Disarm 7 2 Arm Disarm via Phone 7 3 Arm Disarm via SMS 7 4 Trigger Alarm via Keypad...

Страница 5: ...lay intelligent voice guide operation Periodic supervision for wireless PIR and magnetic switch PSTN or GSM dialing or SMS message send for alarm optional Upload and download function optional 255 eve...

Страница 6: ...ng guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference for example...

Страница 7: ...wireless detector magnetic switch siren and keyfobs etc Step 6 Test the communication signal of chosen mounting location Step 7 Permanently install the control panel and transmitters Figure 5 TX TX R...

Страница 8: ...adaptor and plug the backup battery The control panel can not be initialized by only battery Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Ni...

Страница 9: ...ct attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the c...

Страница 10: ...g symbols or marks Selected for multiple choice Unselected for multiple choice Selected for single choice Unselected for single choice Counting down System trouble Display of alarm events Alarm List S...

Страница 11: ...ent alarm way 1 For entry exit zone only during arm away and arm stay will the zone be triggered with alarm delay 2 For active zone only during arm away will the zone be triggered with alarm delay 3 W...

Страница 12: ...will auto release the code While if the code is locked after alarm auto release must be available after system re intialization or within 30 minutes If the code is input wrong the voice will guide Wr...

Страница 13: ...alance for SIM card Commu nication Trouble Trouble There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone There are 22 zones zo...

Страница 14: ...ng Arm or disarm is not available during programming or trouble query Via keypad requires installer code while via keypad requires no code Exit Delaying s When the exit delay ends the voice guide will...

Страница 15: ...isarmed alarm log eliminated 2 Disarm with alarm status saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Disarm 2 0 1 2 2 0 1 0...

Страница 16: ...r confirm Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute 27 28 Through this operation all communication buffers are cleared an...

Страница 17: ...confirm or press to quit To set duress code 1 From the menu select Code Set Duress Code Duress Code Set While you disarm with duress code it will indicate Disarm on site but will dial or send alarm in...

Страница 18: ...digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Voice Phone Interface Set It enables you to select PSTN or GSM as dialling way To set voice ph...

Страница 19: ...n finished Siren test is strongly recommended periodically for safety which includes wired siren wireless siren and built in siren To test siren 1 From the menu select Service 2 Press the navigation k...

Страница 20: ...it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 4 Press to quit after test finish GSM Test To ensure the validity of GSM communication please te...

Страница 21: ...21 22 wired zones Zones No 17 and 19 To set siren function 1 From the main menu select Programming Device Zone Zone Siren Set 2 Use the navigation key to select the zone ending with 3 Then use naviga...

Страница 22: ...nt If the function of Send for service is closed the trouble info will not be sent during enter ir quit programming or zone bypass It will send all event as default 39 40 To send for alarm 1 From the...

Страница 23: ...ttempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence It will not dial again if it exceeds the attempts Comm To set...

Страница 24: ...tion Exit Delay S System 2 Press to edit with icon indication 3 Set the exit delay 0 300s 4 Press to finish and to exit Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature t...

Страница 25: ...While before the message is sent to the station and the telephone line recovers connected well the message will be cancelled Or if the message for Line loss is sent to the station successfully before...

Страница 26: ...rm stay press 2 for disarm press 3 For alarm press 5 Turn on site siren press 6 turn off site siren press 7 for hang up please press 0 repeat Chapter 9 Telecontrol via Phone or SMS Pressing any key du...

Страница 27: ...to the set phone number or SMS center for alarm or system trouble through Contact ID For example the control panel ID is 1234 when fire alarm disarm or zone trouble occurs it will send SMS as followi...

Страница 28: ...et the incorrect telephone number User telephone is busy during alarm Few ringing attempts lead the system to hang up the phone automatically Battery is drained Enroll remote controller without progra...

Страница 29: ...tenance may lead to the system disable Weekly testing is necessary to ensure the system work normally Chapter 12 Warranty and Limitations 53 54 Appendix 1 System Default Parameters No Setting Item Par...

Страница 30: ...Ent Delay Output Trigger PGM Cut off Clear Users Del Superv SV CMS SMS Zone Trb Ind Call Back Reg Dis En Ex Per Line Loss TX Interface Auto ON OFF Wired Test WL Test Built in Test Clear WL Clear Sing...

Страница 31: ...Zone 1 WL Register 1 By Code Learn 2 By Code Input 2 Clear WL 1 Clear Single 2 Clear All 3 Set zone Type 5 Chime Zone Set 4 Zone Siren Set 2 Keyfobs 1 Keyfob Register 1 By Code Learn 2 By Code Input...

Страница 32: ...e entry exit zones active zones perimeter 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be c...

Страница 33: ...Appendix 5 Zone Type Setting Figure Zone NO Installation Position Type Bypass or not 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 61...

Отзывы: