![LOKERMANN GRAND MIG 200 MULTI PFC SYN MV Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/lokermann/grand-mig-200-multi-pfc-syn-mv/grand-mig-200-multi-pfc-syn-mv_user-manual_1938190004.webp)
Maintenance of the arc welding equipment
The arc welding equipment should be routinely maintained according to this manual
recommendations. All access and service doors and covers should be closed and properly
fastened when the arc welding equipment is in operation. The arc welding equipment should
not be modified in any way, except for those changes and adjustments covered in this manaul. In
particular, the spark gaps of arc striking and stabilising devices
should be adjusted and maintained according to our recommendations.
Welding cables
The welding cables should be kept as short as possible and should be positioned close
together, running at or close to the floor level.
Equipotential bonding
Bonding of all metallic objects in the surrounding area should be considered. However,
metallic objects bonded to the work piece will increase the risk that the operator could receive
an electric shock by touching these metallic objects and the electrode at the same time. The
operator should be insulated from all such bonded metallic objects.
Earthing of the workpiece
Where the workpiece is not bonded to earth for electrical safety, nor connected to earth
because of its size and position, for example, ship’s hull or building steelwork, a connection
bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be
taken to prevent the earthing of the workpiece increasing the risk of injury to users or damage to other
electrical equipment. Where necessary, the connection of the workpiece to earth should be made by
a direct connection to the workpiece, but in some countries where direct connection is not permitted,
the bonding should be achieved by suitable capacitance, selected according to national regulations.
Screening and shielding
Selective screening and shielding of other cables and equipment in the surrounding area may
alleviate problems of interference. Screening of the entire welding area may be considered for
special applications.