SECTION 8: STORAGE AND SHIPMENT 

8.1. STORAGE 

The EPIX Digital Imaging System has been 
designed for long-term operation in a normal 
office environment. The system must be 
protected from adverse conditions such as 
excessive moisture, cold or heat. If the 
system is to be stored for a long period of 
time, pack the unit in its original carton. 

While in storage, keep at moderate 
temperatures and protect against moisture 
and humidity. When you are ready to use the 
system again, unpack it and allow the 
scanner to come back to room temperature. 
Then, follow the guidelines outlined in 
Section 5. 

8.2. SHIPMENT 

The EPIX Digital Imaging System is 
designed to be shipped in its original 
shipping container by normal commercial 
carriers. Ensure that the carousel has been 
removed from the scanner and that the 
carousel well is empty. 

If the system is to be moved long distances 
or under adverse conditions, it should be 

protected. This can be accomplished by 
wrapping the EPIX scanner in a plastic bag 
before putting it in the original packing 
materials. 

If you are shipping the scanner, it is 
necessary to park the optics module in the 
center of travel prior to shipment. Contact 
your Logos Imaging dealer for details.

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Digital Imaging System EPIX

Страница 1: ...DIGITAL IMAGING SYSTEM U S Patent Number 5 635 728 User Manual And Installation Guide LOGOS IMAGING EPIXScanner USB LOGOS IMAGING...

Страница 2: ...is a revolutionary new product designed to replace traditional x ray film and film processors TECHNICAL SUPPORT For technical support call you Logos Imaging dealer or Logos Imaging directly SUPPLIES...

Страница 3: ...S 13 Section 5 System Operating Instructions 14 5 1 PREPARING YOUR CURRENT X RAY EQUIPMENT 14 5 2 ERASE THE IMAGING PLATE 14 5 3 TAKING AN X RAY 15 5 4 SCANNING THE IMAGING PLATE 16 5 5 TURNING OFF TH...

Страница 4: ...iographic analysis providing interactive CRT retrieval viewing and processing of stored computed radiographic images The system includes reusable photostimulatable phosphor imaging plates a laser diod...

Страница 5: ...en 100 240 volts AC Imaging plates are toxic The blue colored substance in the imaging plate is toxic Ifpart all of an imaging plate is swallowed contact a physician immediately The physician must rem...

Страница 6: ...sunlight or direct indoor lighting will erase the informationstored on the imaging plate Do not place scanner on or next to a radiator or water source Excessive heat or small amounts of water may dama...

Страница 7: ...Hz Millions of hertz LED light emitting diode mm millimeter cm centimeter kVp peak voltage in thousands of volts IP imaging plates CD ROM compact disc read only CCD charge coupled device TIFF tagged i...

Страница 8: ...8x10 in screen holders 2 8x17 in screen holders 3 8x10 light shields 3 8x17 light shields 1 Logos Imaging software package 1 User manual this manual 1 Software user manual 1 USB cable 6ft 1 Power Cord...

Страница 9: ...canner will not operate with the lid open LED indicator lights with graphic symbols The lights show the current status of the system Green Ready to scan Yellow Scanning Red Error Figure 3 2 Scanner RE...

Страница 10: ...in and 8 x 10 in IMAGING PLATES 8 x 17 in 8 x 10 Plastic mounting strips used to hold imaging plate onto the carousel Active imaging area white color Figure 3 5 CAROUSELS 8 x 10 8 x 17 Top of the caro...

Страница 11: ...er supply auto senses the input voltage Power 100 watts maximum Power Cord Standard line cord provided 3 6 COMPLIANCE TO STANDARDS The EPIX SCANNER Digital Imaging System conforms to the following sta...

Страница 12: ...t countertop large enough to hold the scanner plus provide a working area We suggest a minimum of 18 x 36 in 46 x 92 cm The computer does not need to be on the countertop but must be within the length...

Страница 13: ...relocate your office Inventory the contents of the box and ensure that you have all of the following components If any items are damaged or missing contact your dealer immediately Fig 4 1 Scanner 1 ea...

Страница 14: ...tep 2 Set up the computer and monitor per the manufacturer s recommendations Use an ergonomic setup to minimize repetitive motion injuries Step 3 Turn the power on to the monitor and computer Step 4 C...

Страница 15: ...image information To completely erase the imaging plate expose the front surface blue or white in color to direct intense light for at least 2 minutes An effective way to erase the imaging plate is to...

Страница 16: ...d expose in the usual manner Fig 5 4 In a semi darkened room see Section 4 1 open the screen holder With the white surface pointed away from the carousel insert one side of the imaging plate under the...

Страница 17: ...enough quality erase the imaging plate and start again 5 5 TURNING OFF THE EPIX SYSTEM The EPIX SCANNER Digital Imaging System is designed to be left on continuously The laser is only operational whil...

Страница 18: ...Manual 17 SECTION 6 SOFTWARE OPERATING INSTRUCTIONS Logos Imaging software can capture digital x ray images from the EPIX systems Please refer to the Logos Imaging software user s manual or online hel...

Страница 19: ...is could cause damage to the electronics inside Allow to air dry before plugging in or turning back on Cleaning Imaging Plates Imaging plates should be handled carefully For the best images take care...

Страница 20: ...e cover on the back of the scanner Pry the top of the connector open Fig 7 4 Remove the fuse holder Change both fuses Ensure that new fuses meet the following specifications 250 V 2 amp Time Lag High...

Страница 21: ...n the scanner and computer is loose or defective Reconnect the cable Check for tightness Swap with a known good cable if possible The computer does not recognize that the scanner is connected or the s...

Страница 22: ...ve exposed imaging plates in well lit areas Even in the protective envelope some light penetrates and can partially erase the imaging plates Transfer imaging plates from their protective sleeve to the...

Страница 23: ...Material Items Recycle Comments Plastic Carousel Latches No Dispose of with other non recyclable plastic items Aluminum Housing Optic Module Yes Remove all non aluminum parts before recycling Carousel...

Страница 24: ...t and allow the scanner to come back to room temperature Then follow the guidelines outlined in Section 5 8 2 SHIPMENT The EPIX Digital Imaging System is designed to be shipped in its original shippin...

Страница 25: ...er DHHS Radiation Performance Standards 21 CFR Ch I Subch J EN60825 Class 1 Laser Device Storage and Shipping Conditions 40 to 70 C 40 to 158 F EPIX Imaging Plates Dimensions 8 x 10 in 20 3 cm x 25 4...

Страница 26: ...e with the Logos Imaging written instructions furnished with the unit Please fill out the warranty registration card appendix D and mail to Logos Imaging as instructed EPIX Imaging Plates The EPIX Ima...

Страница 27: ...rtional to the amount of x ray energy the crystal was exposed to The EPIX SCANNER further excites the phosphor crystals to an unstable state by exposing them to a red laser The phosphor crystals then...

Страница 28: ...btain excellent image quality Recommendations on Lighting Conditions for Loading Carousels Fluorescent Lights If loading can be accomplished in less than 60 seconds the fluorescent lighting in the are...

Страница 29: ...Completely erase an imaging plate by subjecting it to direct intense light for about 20 minutes 2 Scan the imaging plate No image should appear on the monitor If an image does appear repeat step 1 wit...

Страница 30: ...d have a minimum of 600 dpi resolution and pseudo randomic dithering Using the standard Windows drivers allows the use of the same printer for all other Windows applications word processing etc The Ep...

Страница 31: ...e continuous improvements to imaging software and you may be interested in some of the upgrades Registering your system with Logos Imaging ensures that you will be promptly notified of any new offerin...