17
15A
5A
30A
80A
5.5 Fuses -
replacement
There are four fuses in the electrical circuit.
80 Amp fuse in the main supply from battery
5 Amp fuse in the control current circuit
15 Amp fuse (plug for extra equipment on the instrument board)
30 Amp fuse for built-in charger
40 Amp fuse for Rotator
Pump unit
5.4 Battery charging
If instructions accompany the battery, these are to be followed.
- Charging must be performed with a charger, suitable for the battery type and
correctly set with the charging voltage for the battery type, see point 2.1. For
connection and operation, see instructions accompanying the charger.
- NOTE! Maintenance-free batteries require a charger, which is intended for
maintenance-free batteries.
- Charging simultaneously with truck operation is not recommended.
- Longest battery life is achieved when charging when battery is:
80% discharged (semi-trak and tubular cell)
70% discharged (maintenance-free)
- Charging of the batteries: Max. once per day
- Semi-trak and tubular cell batteries are to be filled with distilled water after
max. 14 cycles. 1 charging = 1 cycle.
Attention! Why do the fuses
melt?
Do not insert a larger fuse; The fuse acts as a
protector for the pump motor.
Содержание LOGIFLEX ELF
Страница 1: ...LOGIFLEX ELF ELFS Rotator ...
Страница 29: ...29 ...
Страница 30: ...30 ...
Страница 31: ...31 ...