General Description

 

The 

2000CT  Combined  Counter/Tachometers

*

  are  6-decade  seven  segment  LED  display 

instruments based on the industry standard Intel 80C51 series microprocessor.   They are built into 
half DIN (96 mm x 48 mm) panel mounting housings and can be supplied to operate on 115V or 230V 
AC or 24V DC power supplies (see 

Transformer Connections

 on page 5). 

The 

2000CT

 is designed to accept a pulsed signal from either one or two sources and the display can 

be switched to show the rate of the input signal or the total count as and when required.  Both options 
are continuously monitored and either may be instantaneously selected by pressing a button on the 
front  panel. A  high  and  low  alarm  can  be  set  for  the  rate  value  and  the  appropriate  output  will  be 
activated when the value falls outside either limit.   

The displayed values are scaled so that one unit on the display can represent a pre-set number of 
input pulses.   In addition to this scaling there is the facility for individual scaling of the total display 
and the rate display so that rate may be displayed as units per second, units per minute, units per 
hour,  milli-units  per  second  etc.,  and  total  can  be  displayed  as  units,  milli-units,  kilo-units  etc.   An 
option  is  available  for  output  of  the  rate  value  in  a  fully  scalable  analogue  form,  either  current  or 
voltage. 

2000  Series

  instruments  are  available  with  several  factory  fitted  options  which  must  be  specified 

when ordering — see 

Specification

 on page 3 for details.   Additionally, 

Logitech

 will customise the 

programmed operating modes of these instruments to suit specialised applications.  Many variations 
on the standard software have been developed — please contact our Sales Office if this service is 
required. 

Note:  

Two versions of 

2000 Series

 instruments are available - either with a 

full

 switch set accessible 

externally  on  the  front  panel,  or  with  only  a 

single

  function  switch  (

FUNC

)  accessible  unless  the 

bezel and front panel are temporarily removed.  The following setting up instructions assume the front 
panel has been removed if using a 

single

 switch version. 

*

 

 In some industries these type of instruments may be described as “Totaliser/Ratemeters”

2000CT-

MKII

_hb v3.1  01/2020 

 

 

 

 

!

4

Содержание 2000 MKII Series

Страница 1: ...2000 MKII SERIES Counter Tachometer Model 2000CT User Guide...

Страница 2: ...arameters 8 FACTOR 9 TOTAL Scaling Value 9 TOTAL Decimal Point Position 10 RATE Scaling Value 10 RATE Decimal Point Position 10 LOW Alarm 10 HIGH Alarm 10 Analogue Output Settings if O P module ordere...

Страница 3: ...al Signal Inputs Signal B count up Control Inputs Factor protection external Reset Control inputs Opto isolated requires sink to 0V of 220W maximum Outputs DC Voltage 10V nominal unregulated 80mA max...

Страница 4: ...of the total display and the rate display so that rate may be displayed as units per second units per minute units per hour milli units per second etc and total can be displayed as units milli units...

Страница 5: ...black Connect the brown wire to the terminal marked with the letter L or coloured red The mains supply to this instrument must be protected with a 1 Amp fuse Transformer Connections 2000 MKII SERIES...

Страница 6: ...RATE in which case the display will show NO SIG DP Decimal Point Switch This is located under the FUNC switch and is used to set the position of the decimal point as required A single depression of t...

Страница 7: ...hown on the display is equal to or greater than the value programmed into memory The LOW alarm operates on a value equal to or below the programmed value The alarm outputs automatically reset when the...

Страница 8: ...ion Other parameters that may need to be programmed are vi Low Alarm limit vii High alarm limit And if the analogue output option has been specified viii Reference ix Full Scale In order to program th...

Страница 9: ...ues that have been programmed prior to returning the instrument to the RUN mode Otherwise when the required values have been programmed press the RUN SET button once to switch the instrument to the RU...

Страница 10: ...ace to the left on each depression of the lower right hand button This sets the position of the decimal point in the display when RATE is being displayed see iii above vi Low Alarm ALA L When the calc...

Страница 11: ...from rate display to total display The unit will display TOTAL for one second followed by the current total count Note RATE is displayed using a maximum of six digits TOTAL is displayed using up to th...

Страница 12: ...reset prior to using the instrument with the revised programming to avoid the possibility of an incorrectly displayed value which has been held in memory from use with the previous settings Protection...

Страница 13: ...ams Front Panel Layout Note On instruments with the SINGLE switch set option only the FUNC switch is accessible unless the bezel and front panel are removed Rear panel layout 2000CT MKII_hb v3 1 01 20...

Страница 14: ...Connection Diagrams Typical Applications Variable reluctance Magnetic Pickups Single input operation Dual input operation 2000CT MKII_hb v3 1 01 2020 14...

Страница 15: ...Alarm Output Connections Alarm connections with external power supply 2000CT MKII_hb v3 1 01 2020 15...

Страница 16: ...advisable to use a good quality mains filter mounted as close to the instrument as possible ensuring that the cable between the filter and the instrument is kept separate from any cables carrying hig...

Страница 17: ...he warranty only extends to the original user Copyright Logitech Electronics Limited 1994 to 2017 Document No 2000CT MKII_hb v3 0 July 2017 2000CT MKII_hb v3 1 01 2020 17 Design and Manufacture of Ele...

Отзывы: