Revision 1 – 04.12.2015
4/28
TECHNICAL FEATURES
-
Industrial control equipment for the operation and management of screw compressors only, pollution degree 2.
-
In accordance to
EC
Directives:
-
Directive:
-
LVD : 2014/35/UE
-
EMC: 2014/30/UE
-
RHOS: 2011/65/EU
-
based on the following harmonized standards applied:
-
SAF-EMC: EN 60730-1
-
RHOS: EN 50581
-
In accordance to
UL 508 (FILE #: E316817)
.
-
Black auto-extinguishing box in ABS:
-
a)
according EC
: IP64 for the front panel and IP20 for the other parts;
-
b)
according UL
: type 1 and Type 12 for front panel mounting , installation in pollution degree 2 for the other parts
-
Inputs and outputs via terminal-block board to wires (250V, 10A, 12-24AWG) tightening torque 8 Nm.
-
Working temperature: 0°C (32°F) ÷ 50°C (122°F) 90% RH (non condensing)
-
Storage temperature: -20 (-4°F) ÷ +70 °C (158°F)
-
Power supply: 12Vac ± 10% 50 ÷ 60 Hz. (power of the transformer’s secondary: ~ 9 VA) from safety transformer
-
Max. current absorbed = ~ 350 mA
- Visualization through back light alphanumerical LCD 20 digits x 2 rows and nr. 1 led for alarm status
- Messages selectable in 8 languages: Italian – English – French – German – Spanish – Portuguese –
Turkish – Russian
-
nr. 6 key buttons: increase, decrease, enter, reset, start, stop
-
nr. 1 input for temperature probe KTY13.5/NTC 10KOhm@25°C, ß(25/85)= 3977
-
nr. 1 input for pressure transducer (working pressure P1)
-
nr. 1 input for auxiliary pressure transducer (internal pressure P2) or analog information from inverter
-
nr. 1 input for PTC or Klicson for motor protection (IN8).
-
nr. 7 opto isolated digital inputs from 12/24Vac to detect:
IN 1 = emergency stop button
IN 2 = thermal motor
IN 3 = thermal fan
IN 4 = remote start/stop
IN 5 = air filter pressure switch
IN 6 = separator filter differential pressure switch
IN 7 = settable as: door of the electrical cabinet open – control phase relay – generic alarm
-
nr. 3 digital inputs for connection to Logika Control phases unit.
-
nr. 7 outputs via relay with contact 1.5A AC1 250Vac – 6 A AC1 250Vac total
RL1 = line contactor
RL2 = delta contactor
RL3 = star contactor
RL4 = load solenoid valve
RL5 = fan contactor
RL6 = settable as fan contactor, condensate drain, compressor status
RL7 = settable as: alarm, fan contactor, condensate drain, compressor status
- nr. 1 real time clock with buffer battery, around 10 years electrical life
- nr. 1 24Vdc power supply input for PNP outputs
- nr. 1 24Vdc input from inverter to detect inverter fault
- nr. 2 PNP digital output to control the inverter (run and jog command)
- nr. 1 analog output 4÷20 mA for inverter operation
- nr. 2 serial output RS485 for:
connection to other compressor for Master/Slave and/or Multiunit operation
inverter communication
-
Check min. and max. power supply to the controller
-
Non volatile memory to store setting data, working hours, compressor status, alarm list
-
The controller switches OFF due to micro interruption longer than ~ 300 m.s.
Weight: 470 g
Accessories
:
- nr. 1 temperature probe KTY 13.5 for detection of the air end temperature: cable in silicone rubber, length 2.5 m,
working range –10 ÷ 130°C, resolution 1°C.
- nr. 1 pressure transducer 4-20 mA for working pressure control: 2 wires, AISI 316L stainless steel membrane,
working range 0 ÷ 15 bar, resolution 0,1bar, precision ± 0,1bar.
- nr. 1 Logika Control phases unit for power supply 230 ÷ 460V three phase