background image

 

fig. 4 Sub HD 9-pin connector 

Pin # 

Signal 

(EIA / CCITT) 

I/O 

I/O type 

Description 

Comment 

DCD / CT109 

RS232 

STANDARD

RS232 

Data Carrier Detect 

 

TX / CT103 

RS232 

STANDARD

RS232 

Transmit serial data 

 

RX / CT104 

RS232 

STANDARD

RS232 

Receive serial data 

 

DTR / CT108-2 

RS232 

STANDARD

RS232 

Data Terminal Ready 

 

GND 

GND 

Ground 

 

DSR / CT107 

RS232 

STANDARD

RS232 

Data Set Ready 

 

CTS / CT106 

RS232 

STANDARD

RS232 

Clear To Send 

 

RTS / CT105 

RS232 

STANDARD

RS232 

Request To Send 

 

RI / CT125 

RS232 

STANDARD

RS232 

Ring Indicator 

 

 

1.4 Package 

content 

The modem package includes: 

¾

 modem                    

×

1  

 

 

 

 

 

¾

 External AC adapter 

 

 

×

1  

 

 

 

 

 

¾

  RS-232 connecting cable   

×

1  

 

 

 

 

 

¾

 

0dBi 

Antenna 

    

×

1  

 

 

 

 

 

¾

 

User’s 

manual 

    

×

1  

 

 

 

 

 

¾

 

Warranty 

Card 

    

×

1  

 

 

 

 

 

 

 

www.logicbus.com

[email protected]

7 of 27

Содержание LBGSMMODEM31

Страница 1: ...User s Manual LBGSMMODEM31 GSM GPRS MODEM SERIES www logicbus com support logicbus com 1 of 27...

Страница 2: ...minal Equipment PSTN Public Switched Telephone Network DTR Data Terminal Ready PUK Personal Unblocking Key EMI Electro Magnetic Interference RF Radio Frequency ESD Electro Static Discharges RFI Radio...

Страница 3: ...with the modem 13 4 2 Operational status of the modem 14 4 3 Verifying the received signal strength 14 4 4 Verifying the network registration of the modem 14 5 AT commands for the modem 15 6 Troubles...

Страница 4: ...8 2 Prevent embezzlement 24 8 3 Proper usage 24 9 Quality guarantee 24 10 GPRS Modem Internet Access setup guide 25 www logicbus com support logicbus com 4 of 27...

Страница 5: ...cating the operating status External antenna via SMA connector RS232 Serial via 9 pin SUB HD connector Power supply via 2 5mm DC power jack SIM card holder 1 2 Features The main features of the modem...

Страница 6: ...nnection to the antenna Sub D high density 9 pin connector for RS232 serial link connection Power supply connector 2 5mm power jack for DC Power Supply 1 3 1 Power supply connector fig 2 Power supply...

Страница 7: ...2 I RS232 STANDARD RS232 Data Terminal Ready 5 GND GND Ground 6 DSR CT107 O RS232 STANDARD RS232 Data Set Ready 7 CTS CT106 O RS232 STANDARD RS232 Clear To Send 8 RTS CT105 I RS232 STANDARD RS232 Req...

Страница 8: ...CMOS V24 V28 between the internal SIMCOM module DCE and the external world DTE The RS232 interface is protected by ESD protection against electrostatic surges on the RS232 lines Filtering guarantees E...

Страница 9: ...nterface signals However the use of TX RX CTS and RTS signals is mandatory which is not the case for DTR DSR DCD and RI signals which can be not used 2 2 2 Pin out description Signal Pin I O I O type...

Страница 10: ...00 9600 bits s GSM teleservice 62 in Transparent Mode Class 1 Class 2 Group 3 compatible Class 10 Coding schemes CS1 to CS4 Compliant with SMG31bis 1800 MHz E GSM compliant Class 1 1W GSM phase 2 Seri...

Страница 11: ...If the voltage Then falls below 5V The GSM communication is not guaranteed falls below 5 5V The GPRS Class 10 is not guaranteed Voltage over 32V Transient peaks The modem guarantees its own protectio...

Страница 12: ...ture 0 dBm 5 dB 3 3 2 3 External antenna The external antenna is connected to the modem via the SMA connector The external antenna must fulfill the characteristics listed in the table below Table 6 Ex...

Страница 13: ...he RS232 link between the DTE port COM and the modem DCE Configure the RS232 port of the DTE as follows Bits per second 115 200 kbps Data bits 8 Parity None Stop bits 1 Flow control Hardware Flow cont...

Страница 14: ...e table below Table 11 Values of received signal strength Value of received signal strength AT CSQ response Interpretation of the received signal strength 0 10 Insufficient 11 31 Sufficient Greater th...

Страница 15: ...on the network CREG mode 2 Synchronization lost resynchronization attempt Modem synchronization checking AT CREG CREG mode 0 Modem not synchronized on the network no synchronization attempt Receiving...

Страница 16: ...upply in the range of 5 V 5 5V for GPRS Class 10 to 32 V Does the serial cable follow correctly pin assignment shown in paragraph 1 2 1 3 Connect the cable by following pin assignment given in paragra...

Страница 17: ...by the called party Is the selected bearer type supported by the network Enter AT CMEE to view the extended error code Note Refer to Table 15 Ensure that the selected bearer type is supported by the c...

Страница 18: ...ls only No action 40 Network personalization PIN required Network lock Enter Network lock code call your network provider if you don t know this code 103 Illegal MS 3 No action 106 Illegal ME 6 No act...

Страница 19: ...e phone number in the AT command e g ATD Is SIM card configured for data fax calls Configure the SIM card for data fax calls Ask your network provider if necessary No carrier when trying to issue a da...

Страница 20: ...lable 68 ACM equal or greater than ACM max Credit of your pre paid SIM card expired 252 Call barring on outgoing calls 253 Call barring on incoming calls Not applicable 3 6 8 29 34 38 41 42 43 44 47 4...

Страница 21: ...n or both Switch OFF your GSM Modem when at a refueling point Switch OFF your GSM Modem in hospitals and any other place where medical equipment may be in use There may be a hazard associated with the...

Страница 22: ...st If incorrectly installed in a vehicle the operation of GSM Modem telephone could interfere with the correct functioning of vehicle electronics To avoid such problems ensure that the installation ha...

Страница 23: ...7 4 Your Responsibility This GSM Modem is under your responsibility Please treat it with care respecting all local regulations It is not a toy therefore keep it in a safe place at all times and out o...

Страница 24: ...ear quality guarantee We will repair the modem free of charge if quality problems arise from normal using and under normal operation conditions We are not responsible for any related costs or damages...

Страница 25: ...Select Modems in Phone and Modems Options and click Add button 4 Select Don t detect my modem I will select if from a list Select Standard Modems Types Select Standard 33600 bps Modem Select relevant...

Страница 26: ...command AT CGDCONT 1 IP CMNET into textbox Step 3 Establish dial connection 1 Establish Dial Connection Dial number is 99 1 or 99 User name and Password leave empty www logicbus com support logicbus c...

Страница 27: ...he icon from Network Connection to initial connection 3 After initial period the connection is on Note Turn off the power before you insert or remove the SIM card www logicbus com support logicbus com...

Отзывы: