![Loctite MM25 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/loctite/mm25/mm25_operating-manual_1933826030.webp)
30
4 Installation
4.5 Mounting
● Turn the set screws
14
in the thread such that they do not protrude into the coupling
area.
Risk of damage to the fit.
● Check, if the star-shaped couplings
15
are attached onto the coupling of the drive units
A and B. If not, attach it.
● Couple the drive units A and B to the dispensing units until a gap of <1mm is achieved
between the antirotation lock and the dosing units.
● Position the anti-rotation lock correctly by turning the dosing units.
● Easily screw in the set screws
14
with ~ 0.1 Nm of torque. Drive units A respectively B
centered in the correct position.
● First, mount the mounting bracket
21
in
the correct position at the mounting
location. Then attach the pump to the
bracket plate.
Dimensions of the mounting bracket see
section 4.2.
Содержание MM25
Страница 1: ...0 ...
Страница 2: ...2 ...
Страница 6: ...6 2 Gerätebeschreibung 2 1 Bedienelemente und Anschlüsse ...
Страница 24: ...24 2 Description 2 1 Operating elements and connections ...
Страница 39: ...39 7 Annex Edition Ausgabe 04 2013 ...
Страница 40: ......