8
5. Dispensing
5.1 First Operation
5.1.1 Priming the Feed Line
• Purge the stationary applicator of air according to the operating instructions for the
stationary applicator.
Remove the stationary applicator from the holder for purging.
• Perform the filling of the product line according to the operating instructions of the Loctite
®
Controller 97123.
• Before remounting the stationary applicator, adjust the piston stroke (suck-back effect) and the
air outlet chokes (see operating instructions for the Stationary Applicator 97113).
5.1.2 Controlling the Dispensing Sequence
• Place the rotorspray at the wetting position in the part and check the dispensing sequence.
• In the directory MANUAL OPERATION, switch the rotor on and off (see operating instructions for
the Controller 97123). Check whether the rotor rotates.
The rotorspray is automatically switched on at the wetting position by the Controller 97123. The
dispensing takes place automatically after the rotor reaches the rated speed and according to the
preselected dispensing time.
If the dispensed quantity is too small or too large:
• Perform the adjustment of the dispensed quantity according to the operating instructions of the
97123 Controller.
• Reinitiate a start and check the dispensing sequence.
• Repeat the steps until the dispensing sequence is exactly as required and the dispensed
quantity is correct.
5.2 Shutdown
The rotor is switched off automatically at the end of the dispensing time by the Controller 97123.
Shutdown for Longer Periods of Non-use
For pauses in the work of longer than 14 days, place the system out of operation to prevent
curing of the product.
• Unclamp the stationary applicator and put it out of operation according to its operating
instructions.
• Clean the rotor disc according to Section 6.
☞
☞
☞