![Loctite 97115 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/loctite/97115/97115_operation-manual_1933767009.webp)
7
4. Installation (continued)
4.4 Setting Up the Unit
4.4.1 Mounting the Stationary Applicator on the Rotorspray
• Loosen the clamping screws of the holder
4
and clamp in the stationary applicator.
The tip of the flexible dispensing needle must
be placed at a distance of approx. 2 mm from
the bottom of the rotor disc
6
.
When mounting a diaphragm valve use
adapter ring
9
.
4.4.2 Adjusting the Wetting Position
• Place the rotorspray at the wetting position in
the part.
Wetting plane:
At the middle of the holes in the rotor disc.
The rotor disc must be able to reach the
required wetting position exactly without
coming into contact with any obstacles!
4.4.3 Controlling the Mechanical Sequence
• In the main directory PERIPHERY SETUP on the Controller 97123, check whether all of the
necessary connection units are activated (see operating instructions for the Controller 97123).
• In the directory MANUAL OPERATION, switch the rotor on and off (see operating instructions for
the Controller 97123). Check whether the rotor rotates.
☞