Installation
4
4.4
Connecting the Unit
90–260 VAC/47–63 Hz
2 AM
XS1
XS1: Start
XS2: Reservoir
Loctite (Ireland) Ltd.
Made in Germany
cat.no.97102
XS2
5.1
First Operation
5.1.1
Priming the Feed Line
●
Check that the product reservoir, the dispensing valve and the Footswitch are connected correctly
according to their instruction manuals.
☞
To avoid air bubbles during dispensing, the product line must be filled and then purged of air.
●
Position the dispensing valve as specified in its instruction manual to ensure bubble-free filling of the
product line.
Place a container under the dispensing valve since the product will flow out.
●
Switch the power switch
7
to the position
I
(ON).
●
With the pressure regulator
8
, set the
dispensing pressure to 0.50 bar
(approx. 7.00 psi).
●
Press button
until the product flows free of
bubbles from the dispensing needle.
●
For viscous products, increase the pressure
slowly in steps until the product flows out.
Hold the dispensing valve pointing downward
to prevent uncontrolled squirting out of the product.
Dispensing
5
R
CONT
bar
psi
97102
CONT
bar
psi
37