Description
2
2.1
Displays, Operating Elements and Connections
☞
●
See the illustrationon page 3.
1
Digital Display
Display of the dispensing time [s] for a dispensing sequence.
– During dispensing in time controlled mode, the dispensing time remaining is indicated.
– During dispensing in continuous mode, the elapsed dispensing time is indicated.
Display of the dispensing pressure [bar] or [psi] set on the pressure regulator
8
.
Display of error messages (see Chapter 7).
2
Button or
Buttons for changing the dispensing time for a dispensing sequence.
When button
or
is pressed, the display of the dispensing time [s] in the digital display begins to
blink. The dispensing time indicated is increased with button
and decreased with button
.
The dispensing time is adjustable from 0.01 to 99.9 s.
3
Button
Button for the storage of the new values set for the dispensing time [s] and the dispensing pressure
[bar] or [psi].
When the indication of the dispensing time [s] in the digital display blinks, the indicated dispensing
time is stored by pressing button
and the display stops blinking.
For an error message „
Press. 0.83 NOK
“ with beeping, the error message is acknowledged by
pressing button
The value
0.83
[bar/psi] is only an example for the indication of a dispensing
pressure (see Chapter 7).
If the error message „
PRESS ENTER; >Tank Inactive<
“ appears, the automatic reservoir (
Tank
)
is pressurized by pressing (
PRESS
) button
(
ENTER
) (see Section 5.2.1).
4
Button
Button for filling the product line (see Section 5.1.1).
The LED lights as long as button
is pressed.
When button
is pressed in time-controlled mode, the dispensing time is not changed.
The product is dispensed as long as button
is pressed.
When button
in pressed in continuous mode, the dispensing time is changed (see Section 2.3)