MAGLOCK PCB
DOOR SENSOR (Reed SW.)
DOOR SENSOR SENSOR
GREEN
RED
NO
NC
BLACK
Power
Supply
Timer
0-90 sec
-
+
C
CAUTION
Unit may work if jumpers are
incorrectly installed, but will draw
a higher current and may possibly
damage the assembly.
Installation - Electical
Typical Installation
1. Position the jumpers according to the input voltage, and then
fi
nish electrical connection to the door operator.
2.
When the maglock assembly and armature/strike plate are mated, the junction is Normally Open and the LED will turn to green.
3. The remaining three terminals of the terminal block (COM/ NO/ NC) provide an auxiliary relay output which can be used as a door position
switch.
Reed switch dry contacts are
rated max 3w (max switching
contact 0.25 A) for safe operation.
Do not exceed the rating.
* When “SW” is OFF, the Door Status
Sensor (REED SWITCH) detects if the
door is well closed.
** Important: Fix the armature plate not too tightly and make the rubber washer more flexible in order
to make the armature plate automatically adjust its proper position with the magnet