3.
Disassemble the mounting plate from the maglock assembly using the enclosed hex key. Insert 2 screws into the slotted holes and secure the
mounting plate to the doorframe using two of mounting screws. Do not tighten these screws fully until the maglock is properly aligned.
4.
Gently tap (2) 3/16” (5mm) spring pins into the rear side of the armature(s). Drill matching holes on the door to receive these pins.
5.
Align armature/strike plate to magnet, and then drill a 5/8” (16mm) hole in door for sexnut and aluminum reinforcement tube for hollow doors.
Using the M8 x 1.25 x 40mm hex head screw and enclosed hex key, mount armature to door using two metal and one rubber washers.
6.
Continue to fasten mounting plate to heading using remaining screws. Then, reassemble maglock assembly to mounting plate.
7.
Route the enclosed wiring harness through the rectangular hole in the mounting plate. Make the electrical connection as shown below.
8.
Make sure that armature/strike plate can be shaken slightly. This will permit full armature contact and maximize holding force.
Installation - Mechanical
1.
Inspect the frame header to determine if an angle bracket or filler pl
ate is required.
2. Fold the enclosed mounting template on the dotted line and then mark and drill holes as indicated. Drill two 1/8” (3.1 mm) holes at the locations
marked ‘B’. For single doors, locate the template against the door and header on the lock jamb side of the fr
ame.
HEX KEY
MOUNTING PLATE
ASSEMBLY SCREW
MOUNTING PLATE
MOUNTING SCREWS
HEX HEAD SCREW
ARMATURE/STRIKE PLATE
SPRING PIN (2)
SEX NUT
TUBE
WASHER
RUBBER WASHER
WASHER
MAGLOCK
ASSEMBLY