4 NORMAL OPERATION
Installation, user and maintenance manual – LCGHP/LSGHP
17
7.
In the same way: turn the knob to scroll through content (menus, parameters, actions), press the knob to select/confirm the
content (access a menu, display/set a parameter, execute an action, quit or return to the previous level). For example, to quit
the menus, turn the knob to scroll through menus "0.", "1.", "2." etc. until the controller displays the quit screen "E"; now press
the knob to quit.
In the case of menus 0 and 1, the user can view any parameter. For information about menu 2, refer to Paragraph 4.3 p. 17.
To set the parameters of me nu 3, refer to Paragraph 5.8 p. 27. The other menus are not for the User: the information in
these menus is dealt with in the sections dedicated to the installation technician or TAC.
The special key allows the knob of the electronic board to be operated without opening the cover of the electrical panel, so
that operators are protected from live components. When the necessary settings have been completed, put away the special
key, replace the cap on the aperture of the electrical panel and refit the front panel of the appliance.
4�3 RESET OPERATIONS AND MANUAL DEFROSTING
There are several possible reasons why the appliance may have error status and therefore its operation arrested; such an error situa-
tion does not necessarily correspond to damage or malfunction on the part of the appliance. The cause that has generated the error
may be temporary: for example, presence of air in the gas supply line or temporary power failure.
The appliance can be reset with controller menu 2, the Comfort Control Panel (if present) or the DDC (if present). In these two latter
cases, refer to their documentation.
Reset appliance controller
The Table 4.3 p. 17 shows the actions available in menu 2.
For regulatory reasons, the flame controller reset is in a dedicated voice of menu.
Table 4�3 – Menu 2
ACTION
REQUIRED FOR EXECUTION
SHOWN ON DISPLAY AS
20
Reset flame controller arrest
2. 20
21
Reset other operating codes
2. 21
22
Manual defrost
2. 22
23
Timed forcing to minimum power
2. 23
24
Timed forcing to maximum power
2. 24
25
Stop power forcing
2. 25
E
(EXIT MENU)
2. E
The general operating codes of the controller can be reset with functions "20" and "21".
Actions "23", "24" and "25" are used to regulate the combustion parameters or for gas type changeovers, and are thus for use only by
the installation technician or TAC (for other information refer to Paragraph 7.1 p. 54).
RESET FLAME CONTROLLER (ACTION "20"):
Reset flame controller arrest; this may be used when the appliance is first activated, see Paragraph 4.1 p. 14, when the appliance is
in a permanent locked condition or after a long period of disuse (see Paragraph 4.5 p. 18).
You will need: access to the electrical panel, see Paragraph "Display and knob".
To reset the flame control unit select menu 2, as indicated in the Paragraph "Accessing the Menus"; then proceed as follows:
1.
The display shows: "2." press the knob to access the menu. The display initially shows item "2. 20".
2.
Press the knob to display the flashing reset request: "reS1".
3.
Press the knob again to reset the flame controller. The reset request stops flashing, and again the display shows "2. 20". The
reset operation has been performed.
4.
To quit the menu, turn the knob clockwise until the "2. E" is displayed. Now press the knob to return to menu selection: "2.".
5.
To exit the menu selection and return to the normal visualisation of the parameters of the appliance, turn the knob clockwise
until "E" displays; press the knob to quit.
At this point, if the display does not signal any other operating codes, put away the special key, replace the electrical panel
cover and refit the front panel.
RESET OTHER OPERATING CODES (ACTION "21"):
Reset other appliance errors; this is required to reset any errors which may occur during operation.
You will need: access to the electrical panel, see Paragraph "Display and knob".
To reset the controller errors, select menu 2, as indicated in the Paragraph "Accessing the Menus"; Then:
1.
The display shows: "2." press the knob to access the menu. The display initially shows item "2. 20".
2.
Turn the knob clockwise to display item "2. 21".
3.
Press the knob to display the flashing reset request: "rEr1".
4.
Press the knob again to perform a board error reset. The reset request stops flashing, and the again display shows "2. 21". The
reset operation has been performed.