Please read before proceeding

The Knight Fire Tube Boiler Installation 
and Operation Manual along with the 
Knight Fire Tube Boiler Service Manual 
are for use only by a qualified heating 
installer/service technician.  Refer only 
to this User’s Information Manual for 
your reference.  Improper installation, 
adjustment, alteration, service or 
maintenance can cause property damage, 
personal injury (exposure to hazardous 
materials) or loss of life.  Installation 
and service must be performed by a 
qualified installer, service agency or the 
gas supplier (who must read and follow 
the supplied instruction before installing, 
servicing, or removing this boiler.  This 
boiler contains materials that have been 
identified as carcinogenic, or possibly 
carcinogenic, to humans).

Failure to adhere to the guidelines on this 
page can result in severe personal injury, 
death, or substantial property damage.

Boiler service and maintenance –

• To avoid electric shock, disconnect electrical supply 
  before performing maintenance.

• To avoid severe burns, allow boiler to cool before 
 performing 

maintenance.

Boiler operation –

• Do not block flow of combustion or ventilation air to 
  the boiler.  This boiler is equipped with a control which 
  will automatically shut down the boiler should air or 
  vent be blocked.  If vent or air blockage is easily 
  accessible and removable, remove it.  The boiler should 
  attempt to restart.  If blockage is not obvious or cannot 
  be removed, have the boiler and system checked by a 
  qualified service technician.

• Should overheating occur or gas supply fail to shut off, 
  do not turn off or disconnect electrical supply to the 
  circulator.  Instead, shut off the gas supply at a location 
  external to the appliance.

• Do not use this boiler if any part has been under water.  
  The possible damage to a flooded appliance can be 
  extensive and present numerous safety hazards.  Any 
  appliance that has been under water must be replaced.

Boiler water –

• Thoroughly flush the system (without boiler 
 

connected) to remove sediment.  The high-efficiency 

  heat exchanger can be damaged by build-up or 
 

corrosion due to sediment.

• Do not use petroleum-based cleaning or sealing 
  compounds in the boiler system.  Gaskets and seals in 
  the system may be damaged.  This can result in 
  substantial property damage.

• Do not use “homemade cures” or “boiler patent 
  medicines”.  Serious damage to the boiler, personnel, 
  and/or property may result.

• Continual fresh make-up water will reduce boiler life.  
  Mineral buildup in the heat exchanger reduces heat 
  transfer, overheats the stainless steel heat exchanger, 
  and causes failure.  Addition of oxygen carried in by 
  makeup water can cause internal corrosion.  Leaks in 
  boiler or piping must be repaired at once to prevent 
 makeup water.

Freeze protection fluids –

• NEVER use automotive antifreeze.  Use only inhibited 
 propylene glycol solutions, which are specifically 
  formulated for hydronic systems.  Ethylene glycol is 
  toxic and can attack gaskets and seals used in hydronic 
 systems.

When calling or writing about the boiler 
– Please have the boiler model and serial 
number from the boiler rating plate.

Consider piping and installation when 
determining boiler location.

Any claims for damage or shortage in 
shipment must be filed immediately 
against the transportation company by 
the consignee.

Factory warranty (shipped with unit) does 
not apply to units improperly installed or 
improperly operated.

3

 NOTICE

 WARNING

 NOTICE

 WARNING

DO NOT install units in rooms or 
environments that contain corrosive 
contaminants (see Table 1 on page 4).  
Failure to comply could result in severe 
personal injury, death, or substantial 
property damage.

        

          User’s Information Manual

Содержание Knight 285

Страница 1: ...flammable vapors are likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your ga...

Страница 2: ...avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Contents...

Страница 3: ...ler if any part has been under water The possible damage to a flooded appliance can be extensive and present numerous safety hazards Any appliance that has been under water must be replaced Boiler wat...

Страница 4: ...abrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construction...

Страница 5: ...rn water temperature If combustion or performance indicate need Clean heat exchanger Remove and clean burner using compressed air only Clean the blower wheel Owner maintenance see pages 6 8 for detail...

Страница 6: ...Products containing chlorine or fluorine if allowed to contaminate the boiler intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to conti...

Страница 7: ...CTION FROM CONDENSATE VENT ON BOILER FROM CONDENSATE DRAIN ON BOILER DIR 2000507910 00 1 2 PVC UNION FIELD PROVIDED 1 2 PVC TEE RECOMMENDED FIELD SUPPLIED NEUTRALIZER KIT FLOOR DRAIN OR DRAIN PAN User...

Страница 8: ...e technician to inspect the valve and system 4 If water does not flow from the valve when you lift the lever completely the valve or discharge line may be blocked Immediately shut down the boiler foll...

Страница 9: ...9 3 Operating instructions User s Information Manual...

Страница 10: ...ture units can also be changed see page 11 Installer Most parameters are available only to the installer accessible by entering the installer password see the Knight Fire Tube Boiler Service Manual Sa...

Страница 11: ...ngs will be discarded Set domestic hot water DHW operation Verify DHW mode There are two 2 modes of operation for DHW In Normal Mode when a DHW demand begins the control will start the DHW pump turn o...

Страница 12: ...the minutes Press the NAVIGATION dial 8 TurntheNAVIGATIONdialtoadjustthemonth Pressthe NAVIGATION dial 9 Turn the NAVIGATION dial to adjust the date Press the NAVIGATION dial 10 Turn the NAVIGATION d...

Страница 13: ...The call for heat has been satisfied and the unit runs the fan for an additional postpurge period to clear the combustion chamber and vent system of residual flue products SHUTDOWN The unit has been p...

Страница 14: ...mperature of Loop 3 reported by the MTLC control I O SCREEN a GAS PRESS SW The state of the gas pressure switch b FLOW SW The state of the flow switch c LOUVER RELAY The state of the louver relay outp...

Страница 15: ...the Home Status Screen and upload any changes EXIT Press the LEFT SELECT key to go back to the previous Menu Screen YES Press the LEFT SELECT key to accept current operation SKIP Press the LEFT SELECT...

Страница 16: ...Revision Notes Revision A Change 500001290 initial release MM 100267830_DIR 2000508772 Rev A 10 15...

Отзывы: