3.
Install the cables in a pull relief under the electrical section.
4.
Set the appropriate settings in the interface.
Note
Use parameter
002
or
005
to set the ON mode setpoint. The parameter to be used
depends on the value of parameter
004
, refer to the table below.
Control switch ON mode/
OFF mode
(parameter
001
)
External
ON mode
switch
Setpoint EXT mode
(parameter
004
)
Result
Position 0
(OFF)
-
-
-
No functionality
(Anode protection active)
Position I
(ON)
OFF mode
Open
-
Frost protection
Closed
Disabled (
dIS
)
EXT mode
(set setpoint with parameter
002
)
Enabled (
ENA
)
EXT mode
(set setpoint with parameter
005
)
ON mode
Open
-
ON mode
(set setpoint with parameter
002
)
Closed
Disabled (
dIS
)
EXT mode
(set setpoint with parameter
002
)
Enabled (
ENA
)
EXT mode
(set setpoint with parameter
005
)
8.8.3.3 Additional error signal
Note
The water heater has a relay contact that can be used when an error occurs. The relay
contact is potential–free (maximal 5 A).
Note
There is a 1 minute delay between the switching of the relay contact and the error
message on the display.
Install an additional error signal:
1.
Pull the power cable through the tulles.
2.
Connect the cables to X1 and X2.
3.
Install the cables in a pull relief under the electrical section.
n
n
0312582_EcoSword_V4.0, 03-05-2021
49
Содержание EcoSword LGC 160-210 G P CE
Страница 11: ...User part 0312582_EcoSword_V4 0 03 05 2021 11 ...
Страница 12: ...12 ...
Страница 14: ...14 User part ...
Страница 16: ...16 User part ...
Страница 22: ...22 User part ...
Страница 25: ...Installation Maintenance and Service part 0312582_EcoSword_V4 0 03 05 2021 25 ...
Страница 26: ...26 User part ...
Страница 34: ...34 Installation Maintenance and Service part ...
Страница 56: ...56 Installation Maintenance and Service part ...
Страница 68: ...68 Installation Maintenance and Service part ...
Страница 85: ...13 4 Electrical wiring diagram 0312582_EcoSword_V4 0 03 05 2021 85 ...
Страница 90: ...90 Installation Maintenance and Service part ...
Страница 93: ......