background image

20

be  set  for  120°

 

to  180°F  water  temperature,  but  120°F  is  the 

recommended starting point.  It is suggested the dial be placed 

on the lowest setting which produces an acceptable hot water 

supply.  This will always give the most energy efficient operation.  

The temperature control has a 4°F (2°C) fixed differential.

PREVENTIVE MAINTENANCE

CHECK THE IGNITOR ASSEMBLY

At least once a year, check the ignitor assembly, see Figure 11, 

and the main burner, see Figure 12, for proper operation.  Refer 

to the following ignitor assembly and main burner sections.

IGNITOR ASSEMBLY

For access to ignitor assembly, unfasten two screws to burner 

cover and remove.  Locate the burner with the ignitor assembly 

and remove screw holding burner to manifold.  Slide burner out 

to access ignitor assembly.

Servicing of the ignitor assembly includes keeping the ignitor

 free 

of lint, scale or any other foreign debris.

                                             

FIGURE 11

MAIN BURNER

The  main  burner,  see  Figure  12,  should  display  the  following 

characteristics:

•        

Cause rapid ignition and carry across entire burner.

•  Give reasonably quiet operation during ignition, burning, and

 

extinction.

•  Cause no excessive lifting of flame from burner ports.

              

FIGURE 12

If the preceding burner characteristics are not evident, check for 

accumulation of lint, scale or other foreign debris that restricts or 

blocks the air openings to the burner or heater.

WATER TEMPERATURE CONTROL

 

 DANGER

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE 

THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT 

WATER TEMPERATURES REQUIRED FOR AUTOMATIC 

DISHWASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS 

RESULTING IN SERIOUS PERSONAL INJURY AND/OR DEATH. 

THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH 

THE PERSON’S AGE AND TIME OF EXPOSURE.  THE SLOWER 

RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS 

INCREASES THE HAZARDS TO THEM.  NEVER ALLOW SMALL 

CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN 

BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON 

UNATTENDED IN A BATHTUB OR SHOWER.

THE  WATER  HEATER  SHOULD  BE  LOCATED  IN AN AREA

 

WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS 

TO SET TEMPERATURES.

SETTING THE WATER HEATER TEMPERATURE AT 120°F 

(49°C) WILL REDUCE THE RISK OF SCALDS. 

Some states or 

provinces require settings at specific lower temperatures.

Below you will find listed the approximate time-to-burn relationship 

for normal adult skin.  Short repeated heating cycles caused by 

small hot water uses can cause temperatures at the point of use 

to exceed the thermostat setting by up to 20°F (11°C).  If you 

experience  this  type  of  use,  you  should  consider  using  lower 

temperature settings to reduce scald hazards.

 

Water 

Time to Produce 2nd & 3rd

 

Temperature 

Degree Burns on Adult Skin

 

185°F 

Nearly instantaneous

 

180°F  

Nearly instantaneous

 

170°F  

Nearly instantaneous

 

160°F  

About 1/2 second

 

150°F  

About 1-1/2 seconds

 

140°F  

Less than 5 seconds

 

130°F  

About 30 seconds

 

120°F  

More than 5 minutes   

 

 

 

  

Valves for reducing point-of-use temperature by mixing cold and 

hot water are available.  Also available are inexpensive devices 

that attach to faucets to limit hot water temperatures.  Contact a 

licensed plumber or the local plumbing authority.

The water temperature is controlled by a thermostat, see Figure 

3,  which  has  two  sensing  elements.  One  sensor  is  located 

near the top of the tank and the other is near the center. The 

thermostat is set in the lowest position before the heater leaves 

the factory.

The thermostat temperature dial, see Figure 3, is accessible by 

removing  the  control  cover.  The  dial  is  adjustable  and  may 

Содержание CGL150

Страница 1: ...ed in U S A 1011 322880 000 CAUTION TEXT IN BLACK BOLD TYPE OR UNDERLINED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE Thank you for b...

Страница 2: ...installation must comply with the latest editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the National Electrical Code NFPA 70 documents are available from the National Fire Protection...

Страница 3: ...ater is due to a corrosive atmosphere Refer to the limited warranty for complete terms and conditions IMPROPER COMBUSTION WARNING ATTIC AND OR EXHAUST FANS OPERATING ON THE PREMISES WITHAWATER HEATER...

Страница 4: ...n per cubic foot of air Therefore the heater input rate should be reduced at high altitudes for satisfactory operation with the reduced oxygen supply Failure to make this reduction would result in an...

Страница 5: ...DUCER BLOWER ASSEMBLY All units are equipped with a exhaust inducer The inducer assists in drawing in fresh air to the unit for combustion and then assists in dispensing the combustion by products int...

Страница 6: ...ns above 2000 feet 610m refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure LEVELING If the unit is not level insert the bolts which were used in crating into the...

Страница 7: ...ater must be protected from freezing downdrafts Remove all soot or other obstructions from the chimney that will retard a free draft Type B venting is recommended with these heaters This water heater...

Страница 8: ...r well Excessive pressure may develop in such closed systems causing premature tank failure or intermittent relief valve operation This is not a warranty failure An expansion tank or a similar device...

Страница 9: ...ALL GAS PIPE IS CLEAN ON THE INSIDE TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE A DIRT LEG SOMETIMES CALLED SEDIMENT TRAPORDRIPLEG MUSTBEINCORPORATEDINTHEPIPING SEE FIG 9 THE DIRT LEG...

Страница 10: ...h the latest version of the National Electrical Code ANSI NFPA No 70 FIGURE 10 SINGLE UNIT WIRING DIAGRAM must conform to all local code authority having jurisdiction AN ELECTRICAL GROUND IS REQUIRED...

Страница 11: ...emperature and pressure relief valve of adequate capacity is installed on the heater The locations shown in the installation diagrams on the following pages are typical The discharge opening of the te...

Страница 12: ...LD NOT EXCEED SAFE USE TEMPERATUREAT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 20 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FO...

Страница 13: ...BE CLOSED ON DURING THE RINSE OPERATION AND OPEN OFF WHEN DISHWASHER IS NOT OPERATING OR WHEN ON LONG STANDBY NOTE 2 INSTALL LINE TEMPERATURE CONTROL IN AN UNINSULATED TEE BEYOND THE DISHWASHING MACH...

Страница 14: ...in the installation diagrams on the following pages are typical The discharge opening of the temperature and pressure relief valve must be piped to an open drain and should not be subject HEATER WITH...

Страница 15: ...NOTE 3 ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW RATE DOES NOT CAUSE UNNECESSARY TURBULENCE IN THE TANK PIPE RELIEF VALVE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH LOCAL CODES CIRCULATING RETURN LI...

Страница 16: ...RS WITH MIXING VALVE TWO PRE HEATERS WITH BOOSTER HEATER DANGER TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 20 IF HIGHER PREHEA...

Страница 17: ...STER OUTPUT ADD AN ANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES PIPE RELIEF VALVE TO OPEN DRAIN WHEN USING AN LOCHINVAR T 140 200 350 OR 400 STORAGE TANK USE LOWER 3 4 OPENING FOR TANK TEMPERAT...

Страница 18: ...rner before going into lockout After the controller tries three times it will wait one hour before trying to light the unit again This cycle will continue until the main burners are ignited or the uni...

Страница 19: ...tes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this label If you don t smell gas go on to the next step 7 Turn gas control knob counterclockwise to ON...

Страница 20: ...WHICH INJURYOCCURS VARIES WITH THE PERSON S AGE AND TIME OF EXPOSURE THE SLOWER RESPONSETIMEOFCHILDREN AGEDORDISABLEDPERSONS INCREASES THE HAZARDS TO THEM NEVER ALLOW SMALL CHILDRENTOUSEAHOTWATERTAP...

Страница 21: ...essure and input rate 4 Clock the meter as in step 2 above 5 Repeat steps 3 and 4 until the specified input rate is achieved 6 Turn the gas control knob to PILOT Remove the pressure gauge and replace...

Страница 22: ...when removed New pipe collars will insure that the seal is such as to prevent leakage of flue products when properly installed NOTE Anode rod inspection may need to be made more frequently in areas s...

Страница 23: ...calling your service agent the following checklist should be examined to eliminate obvious problems from those requiring replacement or servicing Check that main manual gas shutoff valve is fully open...

Страница 24: ...e complete model and serial number as it appears on the product Refer to the part s list for more information SERVICE The installer may be able to observe and correct certain problems which may arise...

Страница 25: ...engages Prover Switch Ignition Control Board provides power to Silicon Nitride Ignitor Silicon Nitride Ignitor warms up for 20 seconds Ignition Control Board opens Gas Valve Ignition Control Board sh...

Страница 26: ...n Replace dual bulb controller if differential is too wide greater than 4 F Heater recovery is slower Call serviceman Check gas input If incorrect adjust gas pressure or replace main burner orifice Dr...

Страница 27: ...so installed at the heater s and operational at all times The temperature and pressure relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited...

Страница 28: ...28 Copyright 2011 Lochinvar LLC All rights reserved 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Service email 2tech lochinvar com www Lochinvar com...

Отзывы: