3.

 

TECHNICAL CHARACTERISTICS 

U

NIT DESCRIPTION

 

Amicus boost heat pumps are particularly suitable for applications that use source energy at medium or high temperatures.  
These units have been designed to produce water at high or very high temperature for applications where it is necessary to have 
maximum efficiency in heating. The units are available in heating only mode and can produce water up to 80°C. If an external 
3-way valve is used, the appliance can supply both heating and domestic hot water. A wide range of accessories allows you to 
choose the optimal solution.

 

Frame 

All units are made from hot-galvanised sheet steel, painted with polyurethane powder enamel and stoved at 180°C to provide 
maximum protection against corrosion. The frame is self-supporting with removable panels. All screws and rivets used are made 
from stainless steel. The standard colour of the units is RAL 9018.

 

Refrigerant circuit 

The  refrigerant  utilised  is  R134a.  The  refrigerant  circuit  is  assembled  using  internationally  recognised  brand  name 
components with all brazing and welding being performed in accordance with ISO 97/23. Each refrigerant circuit is totally 
independent from the other  with the result that any fault or alarm condition on one circuit does not influence the 
other. The refrigerant circuit includes: sight glass, filter drier, thermal expansion valve with external equalizer, Schrader 
valves for maintenance and control and pressure safety device (for compliance with PED regulations).

 

Compressors 

The compressors used are a high performance scroll type that incorporates a special scroll design which enhances the 
efficiency of the refrigerant cycle when the source temperature is low. The compressors are all supplied with a crankcase 
heater and thermal  overload protection by a klixon embedded in the motor winding. They are mounted in a separate 
enclosure thus enabling them to be maintained even if the unit is operating. Access to this enclosure is via the front panel 
of the unit. The crankcase heater is always powered when the compressor is in stand-by.

 

Source heat exchanger 

Source heat exchanger are braze-welded plates and are made of stainless steel AISI 316. 
The use of this type of exchangers greatly reduces the refrigerant charge of the unit compared to the conventional shell 
and tube  evaporators, and increases the efficiency of the refrigerant loads. The heat exchangers are factory insulated 
with flexible close cell material and are protected by a temperature sensor used as antifreeze protection kit.

 

User exchangers 

The user side heat exchanger is a braze welded, plate type heat exchanger, manufactured from AISI 316 stainless steel. 
All units are supplied with a sub-cooler to enhance the performance of the refrigerant cycle. The user heat exchangers are 
factory insulated with flexible close cell material.

 

Electric enclosure 

The enclosure is manufactured in order to comply with the requirements of the electromagnetic compatibility standards CEE 
EN60204.  Access  to  the  enclosure  is  achieved  by  removing  the  front  panel  of  the  unit.  The  following  components  are 
supplied as standard on all units: main switch, thermal overloads (protection of pumps and fans), compressor fuses, control 
circuit automatic breakers, compressor  contactors, fan contactors and pump contactors. The terminal board has volt free 
contacts for remote ON-OFF, Summer/Winter change over (reversible type only) and general alarm. For all three phase units, a 
sequence relay that disables the power supply in the event that the phase sequence is incorrect (scroll compressors can be 
damaged if they rotate in the wrong direction), is fitted as standard.

 

Microprocessors 

All units are supplied as standard with microprocessor controls. The microprocessor controls the following functions:  
control of the water temperature, antifreeze protection, compressor timing, compressor automatic starting sequence, alarm 
reset, volt  free contact for remote general alarm, alarms and operation LED’s. If required (available as an option), the 
microprocessor can be  configured in order for it to connect to a site BMS system thus enabling remote control and 
management. The technical department can discuss and evaluate, in conjunction with the customer, solutions using 
MODBUS protocols.

 

Control and protection devices 

All units are supplied with the following control and protection devices: Return and supply user heat exchanger sensors, return 
and supply source heat exchanger sensors, high pressure switch with manual reset, low pressure switch with automatic reset, 
high pressure safety valve, compressor thermal overload protection, pump thermal overload protection (when 
present), source heat exchanger flow switch. 

 

 

Содержание Amicus LAHP1202WW

Страница 1: ...EAD AND UNDERSTAND THE INSTRUCTIONS Read and fully understand all instructions before attempting to operate maintain or install the unit Installation manual_Boost heat pump_July2019 Models LAHP302WW L...

Страница 2: ...Information Regarding the Typeof refrigerant used 11 First AidMeasures 11 3 TECHNICAL CHARACTERISTICS 12 Unit description 12 Frame 12 Refrigerant circuit 12 Compressors 12 Source heat exchanger 12 Use...

Страница 3: ...32 Remote wiring connections optional 33 Factory fitted wiring connections 34 Positioning of the user circuit water inlet sensor BTI 35 Positioningofthedomestichotwatercircuitsensor BTS 36 Refrigerant...

Страница 4: ...ccess 49 Periodical checks 49 Every 6 months 49 End of seasons or unit switchedoff 50 Refrigerant circuit repair 50 8 DECOMMISSIONING 50 Disconnecttheunit 50 Disposal recovery andrecycling 51 RAEE Dir...

Страница 5: ...the unit TheyhavebeenpreparedinaccordancewiththeEuropeanUnionlawsandwiththetechnicalstandardsinforceatthedateofissueofthe instructions The instructions contain all the necessary information to preven...

Страница 6: ...n of power cables ensure correct earthing of all metal parts External to unit Poisoning severe burns Fire due to short circuit or Size cables and mains protection overheating of the supply cable Size...

Страница 7: ...ccordancewithISO3864 2 SafetysymbolscombinedinaccordancewithISO3864 2 BANNED Ablack symbol inside a redcircle witha red diagonalindicates anactionthat should not be performed WARNING Ablackgraphicsymb...

Страница 8: ...nelectrical hazard MOVING PARTS The symbol indicates those moving parts of the unit that could create risk HOT SURFACES The symbol indicates those components with high surface temperature that could c...

Страница 9: ...N Eachunithasaratingplatethatprovideskeyinformationregardingthemachine Theratingplatemaydifferfromtheoneshownbelowastheexampleisforastandardunitwithout accessories Forallelectricalinformation not prov...

Страница 10: ...e refer to the information provided on the compressor data plate Main Ecological Information Regarding the Types of refrigerants Fluids used PERSISTENCE AND DEGRADATION Therefrigerantsuseddecomposeint...

Страница 11: ...ess Prolonged exposure may lead to irregular heartbeat and cause sudden death Higher concentrations may cause asphyxia due to the reduced oxygen contentintheatmosphere Contact with skin Splashesofnebu...

Страница 12: ...ompared to the conventional shell and tube evaporators and increases the efficiency of the refrigerant loads The heat exchangers are factory insulated withflexibleclosecell material and are protected...

Страница 13: ...ce water 2 way modulating valve 4 20 mA 0 10 V V2MO 2 waymodulatingvalveisfactoryinstalledinthehydrauliccircuitatthesourceside tooptimizetheconsumptionofwellwaterasa function ofthetemperatureoftheavai...

Страница 14: ...11 4 128 7 167 1 208 3 267 9 324 8 372 9 353 7 430 4 498 7 Peak current A 32 8 35 4 54 2 68 6 85 8 105 6 125 8 171 6 211 2 251 6 Compressors Circuits n n 2 1 2 1 2 1 2 1 2 1 2 1 2 1 4 2 4 2 4 2 Capaci...

Страница 15: ...r The maximum user outlet water temperaturecannotexceed 78 C higher values may call the action ofsafetydevices which wouldstop theunit Source water temperature Theminimumsourcewateroutlettemperatureis...

Страница 16: ...e can calculate the kW output of an indirect coil using the formulae below 1m2 coil kW rating Specific heat capacity water x flow return temperature differential x flow rate l sec or Kw 4 18 x flow re...

Страница 17: ...and pressure drop correction factors are to be applied directly to the values given for operation without glycol The water flow rate correction factor is calculated in order to maintain the same tempe...

Страница 18: ...63 2 59 8 50 7 86 9 73 57 902 87 1 78 3 72 2 70 7 69 6 64 2 60 8 51 7 87 9 74 58 1202 89 1 80 3 74 2 72 7 71 6 66 2 62 8 53 7 89 9 76 60 1402 91 1 82 3 76 2 74 7 73 6 68 2 64 8 55 7 91 9 78 62 1804 91...

Страница 19: ...jects into moving parts HEALTH AND SAFETYCONSIDERATIONS Theworkplace mustbekeptclean tidyandfreefromobjects thatmaypreventfreemovement Appropriate lightingofthework place shall be provided to allow th...

Страница 20: ...mage during transport The delivered goods are conforming to what shown in the delivery note In Case of Damage List the damage on the delivery note InformtheLochinvar Limitedoftheextentofthedamagewithi...

Страница 21: ...astobeinstalledsuchthatmaintenanceandrepairispossible Thewarrantydoesnotcovercostsforthe provision ofliftingapparatus platformsorotherliftingsystemsrequiredtoperformrepairsduringwarrantyperiod Theinst...

Страница 22: ...0 500 2304 1000 500 800 1000 500 2604 1000 500 800 1000 500 INSTALLATION OF RUBBER VIBRATION DAMPERS KAVG Allunitsshouldbeinstalledonvibrationdampersinordertopreventthetransmissionofvibrationtothesupp...

Страница 23: ...dtoasystemwithMODBUSprotocol Thissystem allowsyou to remotely monitor all parameters of the unit and change their values Theserialinterfaceboardisnormallyfittedatthefactory whereitisprovidedseparately...

Страница 24: ...nger In this case the warranty expires immediately TheactivationofthemodulatingvalveV2MOshowsaselectorusedtovarythetypeofsignalandthesenseof rotationof thevalveitself Tamperingcanunderminethecorrectop...

Страница 25: ...wateroutlettemperature Coolingmode 30 35 Cdrybulbambienttemperature 7 Cwateroutlettemperature CHEMICAL CHARACTERISTICS OF THEWATER Thesystemistobefilledwithcleanwaterandventedafterafullflushingoperati...

Страница 26: ...orrosion clogging andfreezingif attributable tolackand or incorrect installation of described safety devices The use of groundwater generally requires approval by the municipality and or the province...

Страница 27: ...Page 27 HYDRAULIC COMPONENTS O Flow Switch N User heat exchanger Q Source heat exchanger O Q N...

Страница 28: ...Page 28 TYPICAL INSTALLATION The pump must be installed with the water supply facing the water inlet connection...

Страница 29: ...red checkallconnections for leaks EMPTYING THEINSTALLATION Before emptying place the mains switch in the Off position Make sure the filling group valve is closed Open the drainage valve outside the un...

Страница 30: ...tbeverifiedthatelectricsupplyiscorrespondingtotheunitelectricnominaldata tension phases frequen cy reported on the label in the front panel of the unit Power cable and line protection must be sized ac...

Страница 31: ...between one phase and another cannot exceed 1 according to EN60204 If those tolerances should not be respected please contact ourLochinvar Limited Model 302 402 602 702 902 Power supply V Hz 400 3 50...

Страница 32: ...configuration the unit microprocessor controller switches off the user water pump when the set pointisreached orifthe unitisin standby This strategy issuitableif the unit isheatingabufferstorefromwhi...

Страница 33: ...33 P a g e Remote wiring connections optional...

Страница 34: ...34 P a g e Factory fitted wiring connections...

Страница 35: ...atureatsetpoint TheBTIsensorisalsousedtoactivatethe userwaterpump and to stop it when the user water temperature set point is reached The BTI sensor MUST be positioned in ordertomeasurethe water tempe...

Страница 36: ...36 P a g e POSITIONINGOFTHEDOMESTICHOTWATERCIRCUITSENSOR BTS Correct positioning of the BTS sensor Incorrect positioning of the BTS sensor OK NO...

Страница 37: ...tary water output probe VMAS Source water modulating valve CH Charging plug 1 4 sae r407 VR Check valve CLP Expansion capillary tube VRV Reverse cycle valve EXV Thermostatic valve YL Liquid solenoid v...

Страница 38: ...no refrigerant leakage Check for oil stains sign of a possible leak Checkthattherefrigerantcircuitshowsthecorrectstandingpressureonthepressuregauges ifpresent otherwiseuseexternalones Check that the...

Страница 39: ...t charge checking Afterseveral hours of operation check thatthe sightglass hasagreen colour core ifthe coreis yellow moistureis presentin thecircuit Inthiseventitisnecessaryfordehydrationofthecircuitt...

Страница 40: ...odeallowsthedisplayofthe differenttemperatures 1click Bottomline displaysEIN Userinletwatertemperature 2clicks BottomlinedisplaysEOUT Useroutlet watertemperature 3clicks Bottomlinedisplays ET Ambientt...

Страница 41: ...ater if required Eachtimethisfunctionisactivated thegreenledpositionedjustabovethebuttonwillbe switchedON Ifpresseddownfor5seconds itmakesitpossibletoswitchtheunitonoroffinheatingmode anddomestichot w...

Страница 42: ...epanel usetherubbergasketRGW V optional Forwallmounting usetheV KITplasticadapter asillustrated in thepicture Electricdatacanbeupdatedwithoutnotice Itisthereforenecessarytoalwaysrefertothewiringdiagra...

Страница 43: ...sure highpressureincooling lowpressurein heatingmode Inprogrammingmodeallowstoscrollthroughtheparametercodesorincreases thevalues Ifpresseddownfor5seconds itmakesitpossibletoswitchtheunitonoroffinheat...

Страница 44: ...circuit heaters activated Led blinking Domestic hot water integrative heaters activated Led OFF Integrative heaters not in operation 3 Led ON Refrigerant circuit 1 activated Whenledcir1and ledcir2are...

Страница 45: ...domestic hot water the microprocessor control will activate the unit in heating mode If the unit is required to operate in cooling and domestic hot water mode the microprocessor control will activate...

Страница 46: ...bymode Itissuggestedtoputtheunitinstandbywhenmodifyingsetpoints Iftheunitisnotinstand by the onlyeditable parametersare the onesrelated to the operation modeof the unit e g In heating mode it is onlyp...

Страница 47: ...edone Inthismenuthereisjustthepossibilitytodisplaytheparameters It isnotpossible to change anyvalue Theparameterlistis Display List Symbol Explanation ALrM Alarm List ALrM See following paragraph ALOG...

Страница 48: ...multiple alarmsusethe keys toscrollthroughthe listof theactivealarms There are two types of alarms Resetalarms RSTlabelappearsontheupperpartofthedisplay Inthiscasepressthe key to reset Nonresetalarms...

Страница 49: ...emachineatleast1 5metersawayfrom externalsurfacesinwhichoperatorsand techniciansonlycan operate must beprovided PERIODICAL CHECKS Thestart upoperationsshouldbeperformedincompliancewithallrequirementso...

Страница 50: ...ully in order to prevent malfunctions Therefore Avoidoilreplenishmentwithproductsthataredifferentfromthatspecifiedandthatarepre loadedintothecompressor Intheeventofagasleakageonmachinesusingrefrigeran...

Страница 51: ...the disposalandrecycling ofelectricalandelectronicequipment mustbehandledthrough aspecial collection inappropriate centres separatefromthatused for the disposalof mixedurban waste Theuserhastheobligat...

Страница 52: ...nit ifthealarm appearsagaincontacttheservice AEFL User water flow switch alarm Presenceofairordirtinessintheuser hydraulic system Bleedcarefullytheuserhydraulicsystem or checkandcleanthewaterstrainer...

Страница 53: ...rost time too long Outside temperature outside the working limits Refrigerant charge leakage Check defrost set point Restore normal working conditions Find leakage and repair b1hP High pressure transd...

Страница 54: ...10 DIMENSIONS See individual drawings for further details Dimensional Drawing Amicus LAHP WW Units 302 402 702 902 1202 1402...

Страница 55: ...Dimensional Drawing Amicus LAHP WW Units 1804 2304 2604...

Страница 56: ...NOTES...

Страница 57: ...NOTES...

Страница 58: ......

Отзывы: