WARNING FOR INSTALLATIONS
FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void
the warranty.
Do not have the vent terminal pointing toward
any opening into a building. Do not locate
your heater in a pit or location where gas and
water can accumulate.
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system
is direct-vented.
Prohibited
Prohibited
Ensure that you meet the minimum clearances
shown below for a direct vent termination:
Ensure that you meet the minimum clearances
shown below for Outdoor vent termination:
Locate the outdoor water heater so it's vent terminal
meets the following clearances. Locate the vent terminal
of an indoor heater to meet the following clearances:
2 ft (61 cm) from an inside corner
2 ft (61 cm) from an outside corner
3 ft (91 cm) below a soffit/overhang
4 � min.
4 � min.
4 � min.
USA: 1 � (30 cm) min.
Canada: 3 � (91 cm) min.
USA: 1 � (30 cm) min.
Canada: 3 � (91 cm) min.
USA: 1 � (30 cm) min.
Canada: 3 � (91 cm) min.
USA: 1 � (30 cm) above grade and
above an�cipated snow level
Canada: 1 � (30 cm) above grade
An�cipated snow level