Instruction Manual
PRECAUTIONS
The following precautions should be taken when working with LMI
®
metering pumps.
Please read this section carefully prior to installation.
Protective Clothing
ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or
near your metering pump. Additional precautions should be taken depending on the solution
being pumped. Refer to Safety Data Sheets precautions from your solution supplier.
Water Pre-Prime
All LMI
®
pumps are pre-primed with water when shipped from the factory. If your solution is
not compatible with water, disassemble the Pump Head Assembly. Thoroughly dry the pump
head, valves, seal rings, balls and
LIQUIFRAM™
DIAPHRAGM. Reassemble head assembly
tightening screws in a crisscross pattern. Refill the pump head with the solution to be pumped
before priming the pump. (This will aid in priming.)
Liquid Compatibility
CAUTION: The evaluation performed by UL was tested with water only. LMI pumps are
EC1783 certified for NSF / ANSI Standard 61 and 372. Please check our listings with NSF
International to confirm approved chemicals and concentrations for use. Always refer to the
solution supplier and the
LMI
®
Chemical Resistance Chart
for compatibility of your specific
LMI
®
metering pump. Contact your local LMI
®
distributor for further information.
Tubing Connections
Inlet and outlet tubing or pipe sizes must not be reduced. Outlet tubing size must not be
increased. Make certain that all tubing is SECURELY ATTACHED to fittings prior to start-up
(see Section 2.3, Tubing Connections)
. ALWAYS use LMI
®
supplied tubing with your pump,
as the tubing is specifically designed for use with the pump fittings. It is recommended that
all tubing be shielded and secure to prevent possible injury in case of rupture or accidental
damage. If tubing is exposed to sunlight, black UV resistant tubing should be installed. Check
tubing frequently for cracks and replace as necessary.
Vinyl Tubing
Your carton may contain a roll of clear vinyl tubing; this is only for connection to the return line
of the
FASTPRIME™
Head and must not be used as discharge tubing.
Ground Fault Circuit Interrupter
WARNING: To reduce the risk of electric shock, install only on a circuit protected by a Ground
Fault Circuit Interrupter (GFCI).
Line Depressurization
To reduce the risk of chemical splash during disassembly or maintenance, all installations
should be equipped with line depressurization capability. Using LMI
®
’s Four-Function Valve
(4-FV) is one way to include this feature.