![LMI ROYTRONIC A Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/lmi/roytronic-a-series/roytronic-a-series_instruction-manual_1932175014.webp)
8
Instruction Manual
2.7 AUTOPRIME™
The AUTOPRIME™ Liquid End is equipped with
a valve that allows for constant removal of vapors
and gasses inherent with effervescent chemicals
such as sodium hypochlorite and hydrogen
peroxide. The valve keeps the pump primed
automatically. When installing a pump equipped
with an AUTOPRIME™ Liquid End connect the
1/2” OD polyethylene tubing to the top vertical
fitting and route this line back to the supply tank.
To ensure priming, this tubing should not be
submerged in the solution. The horizontal fitting
is the discharge and the bottom vertical fitting is
the suction.
Return Fitting
Use 1/2” polyethylene
tubing here and
route to supply tank
Discharge Fitting
Suction Fitting
Figure 8. AUTOPRIME™
SECTION 2 - INSTALLATION