Make  connections  to the furnace junction box from a 120v,  15 amp  fused 

circuit;  black  to black,  white  to white and ground to ground  terminal  located 
inside junction  box.   Solder  and tape or use wire nuts on all connections. 

 

BURNER  LIGHTING 

 

1.  

Add  dry,  (14%-15%  moisture) clean USDA #3 or better)  corn  or pellets  to 

holding  bin.   (See "Important" below) CAUTION:  corn  or pellets  with 
stalks, excess  cob, fines, dirt, etc. may cause the augers  to plug  resulting 
in excessive  wear  and possible auger motor failure.   Burning  treated  seed 
corn  is not  suggested  because of excessive clinker  build  up  and  problems 
with  fire  extinguishing,  caused by the treatment used on the  corn. 

 

**IMPORTANT** Use  of powdered  graphite:  On the initial lighting  of the  furnace, 
add only  approx.  2-3 cups  of corn to the hopper, then add approx.  4-5 
tablespoons of powdered  graphite.  Continue with steps 2 thru  7.  As the  corn 
and graphite  feeds  into  the hopper auger, repeat this procedure  two more  times. 
The powdered  graphite  will lubricate the hopper auger until it begins  to polish 
from the  flow  of the corn  or pellets.  This procedure should  be followed  at the 

beginning  of each  heating  season.  This procedure should  also  be followed  if the 

hopper  is allowed  to empty  and the resulting sticky smoke film coats  the  hopper 
feed auger.   Powdered  graphite may also be added once a month  at a time  when 
the hopper  is low  on fuel, to help keep the auger lubricated  and  polished. 

 

2.  

Turn  on the  electric  power to the furnace. 

 

3.  

Turn  thermostat  to highest  setting. 

 

4. 

 Fill  burner  with  corn  or wood pellets to the lower set of air holes  located  on 
the  inside  of the  burner. 

 

5.  

Liberally  fill  burner  to the top with kindling wood and paper,  light  paper 
and  close  the  door.  NOTE:  Gelled fire starter may be used  as a 
substitute. 

 

6.  

Depress  switch  to start position.  This will activate the combustion  blower 
only.   Continue  to depress switch to start position for three  to five  minutes 
or until  auger  motors are activated.  (Fuel will not begin  to auger  until 
furnace  has  reached  operating temperature and auger  motors  are 
activated.) 

 

7.  

Turn  switch  to "ON" position. 

 

8.  

Set  wall  thermostat  to temperature desired. 

 

9.  

 It may  be necessary  to add kindling wood a couple  of times  before  the 
corn  is completely  ignited. 

 

NOTE:   If the  burner  has been used, all leftover ash and clinkers  must  be 

thoroughly  removed  from the burner before lighting instructions  above. 

 

Содержание America's Heat AH-100

Страница 1: ...OWNERS MANUAL Model AH 100 Furnace 100 000 Btu Model AH 170 Furnace 170 000 Btu LMF MANUFACTURING Manufacturing Facility 900 Park Avenue Woolrich PA 17779 570 769 7775...

Страница 2: ...confidence in that your Americas Heat Furnace will serve your heating needs now and for years to come We ask that you follow our policy of safety first when installing and using your Americas Heat fur...

Страница 3: ...efficient and safe operation Have a qualified service person perform tasks you are not familiar with 8 Caution Children and adults should be alerted to the potentially high surface temperatures of th...

Страница 4: ...Package includes 1 Fuel Delivery Coupler 1 Barometric Draft Control 1 Self Tapping Bolt 1 Hopper Hardware Bag 3 Wire Nut connectors 2 Wooden Handles 2 Insert burner auger assembly into burner auger t...

Страница 5: ...mp securely It is advisable to install two sheet metal screws not supplied thru the clamp auger boot and into the hopper bin outlet to insure a permanent connection Install fuel delivery coupler betwe...

Страница 6: ...nnect the Americas Heat furnace to a lined masonry chimney acceptable to the authority having jurisdiction USA installation may also use a residential type and building heating appliance chimney Canad...

Страница 7: ...I Fig 1 YllUl...

Страница 8: ...ol See Installation Adjust ment If flue pipe is made of material too heavy to bend out into collar make the diameter of the opening within lh of the inside diameter of the collar THERMOSTAT WIRING Con...

Страница 9: ...d be followed at the beginning of each heating season This procedure should also be followed if the hopper is allowed to empty and the resulting sticky smoke film coats the hopper feed auger Powdered...

Страница 10: ...red wire Blower speed can be changed by accessing the other wires behind the left side air filter Disconnect the black to black wire and reconnect to the desired colored wire using existing wire nut...

Страница 11: ...ner with a furnace poker or equivalent tool 2 Check corn or pellet level in holding bin for adequate supply Weekly 1 Check contents of ash drawer and empty as needed Ashes should be placed in a metal...

Страница 12: ...re the precise draft control A setting of 02 03 is ideal In most installations the counter weight on the automatic barometric dampers should be set on the minimum setting Adjusting the on and off cycl...

Страница 13: ...11 REPAIR PARTS Cabinet ModeiBM 620 9...

Страница 14: ...TRIM 9 6440 ASH DRAWER TRIM 1 Jo A 6040 FURNACE FLOOR 11 6220 FRONT PANEL 12 6200 COLD AIR WALL 13 6280 15_ IDE PANEL LEFT OR RIGHT HANDED FURNACEL 14 6240 RIGHT SIDE PANEL AUGER HOLE Ot _THE_RIGHT SI...

Страница 15: ...12 REPAIR PARTS Model AH 170 Cabinet 11 16 Q 18...

Страница 16: ...7 A 4180 BURNER DOOR 8 6460 DOOR TRIM 9 6440 ASHDRAWER TRIM 10 A 6040 FURNACE FLOOR 11 6220 FRONTPANEL 12 5050170 BLOWER HOUSING 13 6280170 BLANK SD I E PANEL LEFT OR RIGHT HANDEDFURNACE 14 6240 RIGHT...

Страница 17: ...r 4 3 KEY PART NUMBER PART DESCRIPTION 1 5700 BURNER HEAT SHIELD 2 5680 HEAT DEFLECTOR 3 5660 SIDE HEAT SHIELD 4 5640 TOP HEAT SHIELD 5 A 5720 HEAT EXCHANGER 6 2200 WOODEN HANDLE 7 2040 5 16 x 1 SHOUL...

Страница 18: ...REPAIR PARTS Electrical tJ 20 6 14...

Страница 19: ...NG 12 1360 JUNCTION BOX 4 X4 13 1400 JUNCTION BOXCOVER 4 X4 14 1300 EMT CONDUIT 36 LONG 15 1640 FAN UMITCONTROL 16 1840 COMPLETE BLOWER 1 7 2080 FURNACE FILTER 20 X20 X 1 18 1860 COMBUSTION BLOWER 19...

Страница 20: ...7 A 4180 BURNER DOOR 8 6460 DOOR TRIM 9 6440 ASH DRAWER TRIM 10 A 6040 FURNACE FLOOR 11 6220 FRONT PANEL 12 5050170 BLOWER HOUSING 13 6280170 BLANK SIDE PANEL LEFT OR RIGHT HANDED FURNACE 14 6240 RIG...

Страница 21: ...REPAIR PARTS Furnace Auger PART DESCRIPTION FURNACE AUGEFrMoTOR LOCK COLLAR 1 4 x 1 2 SELF TAPPING SOLT BURNER AUGER cc c c c SHEET METAL SCREW 10 x 1 3 4 r A U G _E R 8 U PPORT 6 x 6 BOX 16...

Страница 22: ...f 9 10 KEY PART NUMBER PART DESCRIPTION 1 A 3220 HOPPER AUGER 2 3180 LOCK COLLAR 3 1880 HOPPER AUGER MOTOR 4 1410 6 x 6 BOX 5 A 3070 AUGER SUPPORT 6 2070 SHEET METAL SCREW 10 1 3 4 7 7530 RUBBER TEE 8...

Страница 23: ...17...

Страница 24: ...F731 BLOWER COMPLETE 2 4C710 WHEEL 3 A40152 MOTOR MOUNTING BRACKET 4 2C355 HOUSING SUPPORTS 5 8122420 VIBRATION PADS 6 HEX HD MACH SCREW 10 24 x 7 8 7 NUT 10 24 8 HEXHD THREAD CUTTING SCREW 10 x 3 _ 9...

Страница 25: ...BLOWER AH 170 ASSEMBLED DIRECT DRIVE FURNACE BLOWER 18a...

Страница 26: ...REPAIR PARTS Storage Bin Model KEY PART NUMBER PART DESCRIPTION 1 7520 BIN LID f 1 2 7500 BIN CAVITY 1 3 7510 BIN BASE 19...

Страница 27: ...ating it with a return air system a return air plenum must be built The size of the plenum opening can be up to 21 x 21 square Before installing the plenum the air filters and filter rack may be remov...

Страница 28: ......

Страница 29: ......

Страница 30: ...rm below and return this form along with the defective part within five 5 days If defective part is not returned within the allotted time your credit card will be charged Full Name of Buyer Address Ci...

Отзывы: