INITIAL SETTINGS
See Automation Correct Corn-trol Manual.
Thermostat is preset at factory according to the model and auger motors. The
AH-170 can be set to run at a lower btu with an adjustment to the thermostat settings.
MAINTENANCE
Daily
1. Inspect burner. Clinkers will be pushed out of the top of the burner as fuel is
augered into the burner. Clinkers that appear to be stuck to the side of the burner
should be wiggled loose. Large clinkers that may appear must be manually
pushed over the top of the burner with a furnace poker or equivalent tool.
2. Check corn or pellet level in holding bin for adequate supply.
Weekly
1. Check contents of ash drawer and empty as needed. Ashes should be placed in a
metal container with a tightly fitting lid. The closed container ashes should be
placed on a non-combustible floor or on the ground, well away from combustible
materials pending final disposal.
2. Pull flue scraper all the way out and push back in, this maintains the efficiency by
removing ash from the heat exchanger tubes.
3. Check filters.
Monthly
1. Replace filters.
Annually
*** IMPORTANT ***
1. Remove and inspect all chimney pipe connections; clean out ash build up.
2. Clean, oil, and inspect all blower and auger motors.