Declares that 

LK 201 & 202 SmartSolar 

complie with the following directives: 2006/95/EC (LVD), 2004/108/EC (EMC), 97/23/EC 

(PED)

CONFIRMS ALSO THAT

 the product is according to art. 3, paragraph 3 in 97/23/EC directive

The conformity was checked in accordance with the following EN standards:

EN 12164:2001, EN 12165:1999

Copper and copper alloys...

EN 1503-4:2003

Valves. Material for bodies, bonnets and covers. Copper alloys specified in European 
Standards

EN 12516-3:2003

Valves. Shell design strength. Experimental method.

EN 12266-1:2004

Testing of valves. Pressure tests, test procedures and  acceptance criteria. Mandatory 
requirements.

EN 60335-1:2001

Safety of household...

EN 60335-2-51:2003

Safety of household. Particular requirements for stationary circulation pumps for heating 
installations.

EN 61000-6-2:2005

EMC. Immunity for industrial environments

EN 61000-6-3:2007

EMC Emission for recidential, commercial and light industrial environments

Helsingborg, 08 June 2012

Magnus Eriksson
Managing Director

CE DECLARATION OF CONFORMITY

1

4

2

3

5

6

7

LK Armatur AB

Garnisonsgatan 49 • SE-254 66 Helsingborg • Sweden
Tel: +46 (0)42-16 92 00 • Fax: +46 (0)42- 16 92 20
[email protected][email protected]
www.lkarmatur.se

1

2

2

Art.nr

148525-3

youtube.com/lkarmatur

Содержание SmartSolar LK 201

Страница 1: ...SmartSolar LK 201 INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D INSTRUCTION MANUALE DI ISTRUZIONI ASENNUS JA KÄYTTÖOHJE INSTRUKTIONSMANUAL ...

Страница 2: ...sensor is optional The sensor cables can be extended up to a length of 100 m To thiseffect acablecrosssectionof2x1 5mm isrecommended The sensors are to be mounted according to the SmartSol As sembly and Operating Instructions Attention The sensor cables must not contact pipes valves or power cables Use plastic straps to separate them All pipes connected to the solar pump unit must be insulated To ...

Страница 3: ...in Zusatzfühler kann als Zubehör nachbestellt werden Die Fühler werden laut der SmartSol Montage und Bedienungs anleitung installiert Die Fühlerleitungen können bis zu einer Länge von 100 m verlängert werden Dazu wird ein Leitungsquerschnitt von 2 x 1 5 mm emp fohlen Achtung DieFühlerleitungendürfenkeinendirektenKontaktmit Rohren Ventilen oder Starkstromkabeln haben Alle Rohre zur Solarstation sol...

Страница 4: ... en contact avec les tuyaux soupapes ou câbles d alimentation Utilisez des attaches de câble en plastique pour les séparer Tous les tuyaux reliés à la station doivent être isolés Afin d éviter la corrosion des différents composants et des joints nous conseillons d utiliser du mono propylène glycol comme fluide caloporteur MISE EN SERVICE Voir illustration 2 ci après La pression préréglée du vase d...

Страница 5: ... 5 mm I sensori vanno installati attenendosi alle istruzioni per l utilizzo e il montaggio di SmartSol N B I cavi dei sensori non devono entrare in contatto diretto con i tubi le valvole o i cavi di alimentazione Utilizzare fasc ette per separarli Tutti i tubi collegati al gruppo di circolazione vanno isolati Per evitare corrosione si raccomanda l utilizzo di monopropilen glicole come fluido conve...

Страница 6: ...ri TS2 varaajan anturi ja TS3 ylimääräinen anturi Yhden lisäanturin voi tilata lisävarusteena Anturit asennetaan SmartSol Asennus ja käyttöohjeen mukaan Anturien johtoja voidaan pidentää aina 100 m pituisiksi Johtojen poikkipinta alaksi kannattaa tällöin valita 2 x 1 5 mm Varoitus Anturien johdot eivät saa olla suorassa koske tuksissa putkien venttiilien tai vahvavirtajohtojen kanssa Käytä nippu s...

Страница 7: ...rkablarna får inte vara i direkt kontakt med rör ventiler eller starkströmskablar Använd buntband för att skilja dem åt Alla rör som kopplas till drivpaketet skall isoleras För att undvika korrosion och frätning av komponenter och gängtätningar rekommenderas monopropylenglykol som värmebärare DRIFTTAGNING Se bild 2 på baksidan Expansionkärlets förtryck är normalt 1 5 bar Förtrycket skall vara 0 3 ...

Страница 8: ...ll design strength Experimental method EN 12266 1 2004 Testing of valves Pressure tests test procedures and acceptance criteria Mandatory requirements EN 60335 1 2001 Safety of household EN 60335 2 51 2003 Safety of household Particular requirements for stationary circulation pumps for heating installations EN 61000 6 2 2005 EMC Immunity for industrial environments EN 61000 6 3 2007 EMC Emission f...

Отзывы: