  Do not spill water or other liquids on the compressor .These parts are not waterproof. 

If liquid spills on these parts, please unplug the power cord and wipe off the liquid with 
gauze or other soft absorbent material immediately.

  Do not use or store the device in humid locations or outdoors. Use the device within 

the operating temperature and humidity.

  Do not overload power outlets. Plug the device into the appropriate voltage outlet. 

  Do not use extension cords. Plug the power cord directly into the electrical outlet. 

 Unplug the power cord from the electrical outlet after using the device. Never leave this 

product unattended when plugged in.

 Unplug the power cord from the electrical outlet before cleaning the device. 

 Completely read all of the instructions included the optional accessories before using 

them. 

  Not to position the ME EQUIPMENT so that it is dif

fi

 cult to operate the disconnection 

device.

  The power switch is used to isolate the device from the supply mains.

  The direction of movement of the actuator of the supply mains switch is comply with 

IEC 60447.

MAINTENANCE AND STORAGE

  Keep the device out of the reach of unsupervised infants and children. The device 

may contain small parts that can be swallowed. 

  Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts 

with clean hot tap water after disinfecting. 

  Wash the nebulizer parts after each use. Dry the parts immediately after washing.

  Do not store the air tube with moisture or medication remaining in the air tube. This 

could result in infection as a result of bacteria.

  Store the device and the components in a clean, safe location. 

  Do not carry or leave the nebulizer with medication in the medication tank.

  Do not place or attempt to dry the device, components or any of the nebulizer parts in a micro-

wave oven.  

  Do not wrap the power cord around the compressor (main unit). 

The followings are maintenance and repair which can be taken by operator, or which 
must be operated by manufacturer or distributor.

SERVICE AND MAINTEMANCE

RESPONSIBLE

Change the inhalation tube  

Operater

Change the applied part

Operater

Change the air 

fi

 lter

Operater

Clean the surface of the device

Operater

Daily cleaning and disinfecting

Operater

All components which need to be repaired or 
changed by seperating the device

Authorized service center of distrib-
utor or manufacturer

Содержание LD-221C

Страница 1: ...LD 221 Compressor Nebulizer LD Instruction Manual LD ENG RUS...

Страница 2: ...ENG 16 PARTS AND COMPONENTS LD 221C...

Страница 3: ...llow LD N001 Inhalation baffle mainly the lower respiratory tract Consist of two parts cone and cylinder Expendable material 9 3 Baffle C Red LD N003 Inhalation baffle mainly the upper respiratory tra...

Страница 4: ...n solution residual volume and reliable and simple use We thank you for your choice GENERAL INFORMATION Compressor nebulizer LD is designed for treating the diseases of respiratory passages and lungs...

Страница 5: ...ates normally Do not use the device if the air tube is bent Do not block the air filter cover Do not alter the baffle the nozzle in the medication tank or any part of the nebulizer kit Do not add more...

Страница 6: ...NTENANCE AND STORAGE Keep the device out of the reach of unsupervised infants and children The device may contain small parts that can be swallowed Do not leave the cleaning solution in the nebulizer...

Страница 7: ...e first time it is nec essary to make a full cleaning as described in last paragraph SAFETY INFORMATION 1 Place the nebulizer in front of you on the table Make sure the device is turned off power swit...

Страница 8: ...of baffle the particles of different sizes are dis tributed aerosols as follows particle sizes mkm to the total mass 0 5 10 15 1 100 60 30 10 7 5 3 mainly the upper respiratory tract Dispenser C red D...

Страница 9: ...on and reducing aerosol loss when exhaling The effec tiveness of inhalation using the breath actuated nebulizer is increased significantly INHALE EXHALE Completing the inhalation When the inhalation s...

Страница 10: ...mask LD N040 1 9 Inhalation tube LD N051 1 10 Adult nasal nozzle LD N058 1 11 Child nasal nozzle LD N059 1 12 Inhalation filter LD N055 5 13 Instruction Manual 1 14 Warranty Card 1 15 Packaging 1 16...

Страница 11: ...Net Weight no more 1400 g Protection against electric shock type BF Measured by Little Doctor International S Pte Ltd SYMBOLS CE marking in conformity with EC directive 93 42 EEC Important Read the ma...

Страница 12: ...TATE REGISTRATION This device manufacturing is certified according to international standard ISO 13485 Device comply with the requirements of European Directive MDD 93 42 interna tional standards EN 1...

Страница 13: ...ENG 27 Authorized Representative in the EU Little Doctor Europe Sp z o o 57G Zawila Street Krakow 30 390 Poland...

Страница 14: ...I584 2101 09 Little Doctor International S Pte Ltd Little Doctor International S Pte Ltd 2020 UA TR 001 WWW LITTLEDOCTOR SG...

Отзывы: