manualshive.com logo in svg
background image

 
 
 
 
 
 
 
 

Description:   

The 3M Adflo Powered Air Respirator is a respiratory protection 

device, for increased comfort and safety during welding and allied 

processes when used as a system in combination with approved 

headtops. 

3M Adflo Powered Air Respirator is equipped with a particle filter, 

spark arrestor, pre filter and a particle filter indicator that displays the 

level of particle filter clogging. A range of gas filters (optional) give 

additional protection against certain gaseous contaminations. 

3M Adflo Odour Filter (optional) reduces unpleasant odour.  

3M Adflo Powered Air Respirator incorporates an automatic airflow 

control that ensures a constant supply of air during use. An electronic 

control unit provides an audible and visible warning of low battery 

and/or low air flow into the headtop. 

3M Adflo Powered Air Respirator offers a standard and a heavy-duty 

(optional) battery. 

The airflow creates positive pressure which together with the sealing 

to the face prevents particles and other contaminants from entering 

the head top.  

The Adflo unit has a three bar battery indicator. When all bars are 

illuminated the battery has full capacity. 

In addition the Adflo unit also has a five step particle filter indicator.  

Applications: 

The Adflo Powered Air Respirator is designed to provide a supply of 

filtered air from the Adflo unit, via a breathing tube, to a head top. The 

equipment can be used in environments which have a required 

minimum protection factor of 50. The choice of breathing equipment is 

governed by the concentration and type of contamination found in the 

ambient air. 

The complete system protects against particulate contamination and if 

the gas filter is used, against certain gaseous contamination. 

Standards:   

The complete system is a breathing protection device complying with 

Australian and New Zealand Standard AS/NZS 1716 Respiratory 

protective devices. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

Operating instructions: 

Switch on 3M Adflo Powered Air Respirator by pressing the ON button 

once (nominal airflow), twice (airflow plus). Pressing the ON button a 

third time will make 3M Adflo Powered Air Respirator return to nominal 

airflow. 

One green indicator = nominal airflow (see technical specification) 

Two green indicators = airflow plus (see technical specification) 

To switch 3M Adflo Powered Air Respirator off, press the OFF button 

for at least 1 second. If the red light illuminates together with an 

audible warning, this indicates that the airflow is too low (less than 

manufacturer’s minimum design flow rate). If the low flow alarm is 

active for more than two minutes, 3M Adflo Powered Air Respirator 

will automatically turn off. 3M Adflo Powered Air Respirator has a 

three bar battery indicator showing remaining capacity. When the last 

bar starts flashing and an audible warning is heard, less than 5% 

battery capacity is remaining. The warning sound will change 

noticeable after a while and 3M Adflo Powered Air Respirator will turn 

off automatically. See below table for details. 

 

Fault 

Probable Cause 

Action 

Continuous short 

tones 

Red indicator 

lights

 

1. Breathing tube 

blocked 

2. Filter clogged 

3. Filter Cover 

blocked

 

Check and remove 

blockage or obstruction 

Check air inlet to filter 

and remove obstruction, 

change filter

 

Continuous short 

tones 

Battery indicator 

flashes

 

Low battery 

voltage 

Charge the battery 

 

Install a charged battery 

The respirator 

shuts off after 20 

seconds

 

Low battery 

voltage

 

Charge the battery 

Install a charged battery

 

No flow, no alarm

 

1. Battery contact 

damaged 

2. Battery 

completely flat

 

Check battery contact 

 

Charge battery

 

 

 

 
 
 
 
 
 
 
 
 

Отзывы: