Limitations of use: 

 Only use with original 3M Speedglas brand spare parts and 

accessories listed in the reference leaflet and within the usage 

conditions given in the Technical Specifications.  

 

The use of substitute components or modifications not specified 

in these user instructions might seriously impair protection and may 

invalidate claims under the warranty or cause the product to be 

noncompliant with protection classifications and approvals.  

 

3M Adflo Powered Air Respirator must not be used in the 

power OFF state since a rapid build-up of carbon dioxide and 

depletion of oxygen within the headtop may occur. 

 

 Do not remove the headtop or turn off 3M Adflo Powered 

Air Respirator until you have vacated the contaminated area. In the 

power OFF state little or no respiratory protection is expected. 

 

3M™ Adflo™ Powered Air Respiratory System must not 

be used if 3M Adflo Powered Air Respirator does not supply enough 

air (low flow alarm). 

 

3M Adflo Powered Air Respiratory System must not be 

used in flammable or explosive environments. 

 

 Note that the breathing tube might make a loop and get 

caught up by something in the surrounding area. 

 

 If you are not sure about the concentration of airborne 

pollutants, ask an occupational hygienist or safety professional. The 

manufacturer is not responsible for injury following incorrect use or 

incorrect choice of equipment. 

 

Always correctly use and maintain the product according to these 

instructions. Failure to do so may cause fire or explosion or could 

adversely affect respirator performance and result in injury, sickness 

or death. 

  

Do not open, crush, disassemble, dispose of in fire, heat above 

60°C or incinerate. 

  

To avoid damage to the equipment do not use solvents for 

cleaning. Do not immerse in water or spray directly with liquids. Do not 

wipe the electrical contacts. 

 

 

The particle filter indicator reflects particle clogging only. The 

service life of the gas cartridge, when used, must be estimated 

independently in accordance with a change out schedule. Failure to 

do so may result in sickness or death. 

 

 

 

 

 
 
 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical specification 

 

Weight 

   3M Adflo Powered Air Respirator  

   (incl. P-filter, excl battery) 

   

 

 

 

     690 g 

 

 

Manufacturers minimum design flow 

rate 

Nominal airflow 

Airflow Plus 

 

 

 

160 l/m 

170 l/min 

200 l/min 

 

 

Belt size 

 

75-127 cm 

 

 

Operating temperature 

 

-5ºC to +55ºC 

 

 

Battery life 

 

App. 500 charges 

 