5. Fan Assembly.
Loosen canopy set screw and lower
canopy to expose hanging bar. Separate
electrical wiring and safety cable from
rubber band. Lift fan onto j-hook hanging
bracket and slide rubber bushing over
hook.
Make the wiring connections as
shown in Section 6 on the following page.
IMPORTANT
: Find a secure attachment
point (wood ceiling joist highly
recommended) and secure safety
cable--
refer to diagram on the following
page as well
. Use a heavy duty wood screw,
washer and lock washer (not supplied)
over safety cable loop.
Adjust safety cable length by loosening
screw and nut on safety cable vice. Adjust
slack to a hand's length and tighten nut on
vice securely. The loop at the end should
just fit over the threads on the wood screw.
Test cable by pulling on loose end of cable
with pliers. If cable slips, then vice and nut
must be set tighter.
Extra cable slack can be left in ceiling area.
NOTE
: The important safety precautions and
instructions appearing in the manual are not
meant to cover all possible conditions and
situations that may occur. It must be
understood that common sense and caution
are necessary factors in the installation and
operation of this fan.
page 5
j-hook
hanging bracket
canopy set screw
electrical wiring
safety
cable
hanging
bar
canopy
rubber
bushing
ground wire
(green or bare)
vice
loop
nut
screw
motor
housing