6. Wiring.

wall control

wall control

back plate

back plate

screw

back plate screw

safety cable

wood screw

and washer

hanging bar

wood joist

black

white

black

green/ground

bare/ground

from fan

white

*

black

black

AC IN

black

AC IN

black

AC TO FAN

black 

AC TO FAN

black

*

wall control

wire

from 

ceiling

CAUTION

Be sure outlet box is properly 

grounded and that a ground wire (

GREEN

 or 

Bare) is present.

Make sure all electrical connections comply 
with Local Codes or Ordinances and the 
National Electrical Code. If you are unfamiliar 
with electrical wiring or if the wires in the 
house/building are different colors than those 
mentioned below, please consult with a 
qualified electrician.

Connect 

BLACK

 wire from fan to 

BLACK

 

wire from ceiling. Connect 

WHITE

 wire from 

fan to 

WHITE

 wire from ceiling. Connect 

GREEN 

wire from

 

fan to 

BARE

/

GREEN

 wire 

from ceiling. Use wire connectors provided 
when making connections.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure. 
Turn spliced/taped wires upward and gently 
push these wires and wire connectors into 
outlet box.

7. Wiring - Wall Control

Remove existing wall switch. Remove wall 
control back plate by removing 2 screws on 
the wall control--one on the top and one on 
the bottom. Secure wall control back plate 
to wall or structure with screws from 
existing wall switch.

Connect 

BLACK

 wire from wall control to 

BLACK 

(

AC TO FAN

)

 

wire from wall. 

Connect 

BLACK 

wire from

 

wall control to 

BLACK 

(

AC IN

) wire from wall. Use wire 

connectors provided when making 
connections.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.  
Turn spliced/taped wires upward and gently 
push these wires and wire connectors into 
back plate.

Re-attach wall control to back plate using 
the 2 screws that were previously removed.

wall

fan/
motor housing

Содержание BR56TBC3M

Страница 1: ...g 4 Fan Assembly pg 5 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Wall Control Operation pg 7 Testing Your Fan pg 8 Troubleshooting pg 8 Parts Replacement pg 8 Warranty pg 8 net weight of fan...

Страница 2: ...t only one 12 gauge house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an...

Страница 3: ...nserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included a j hook hanging bracket 1 piece b blade 3 pieces c motor housing downrod and can...

Страница 4: ...fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existi...

Страница 5: ...nd nut on safety cable vice Adjust slack to a hand s length and tighten nut on vice securely The loop at the end should just fit over the threads on the wood screw Test cable by pulling on loose end o...

Страница 6: ...ire from fan to BARE GREEN wire from ceiling Use wire connectors provided when making connections Wrap each wire connector separately with electrical tape as an extra safety measure Turn spliced taped...

Страница 7: ...nd attach the blade with 2 of the washers and blade screws that were just removed as shown Tighten both blade screws securely Repeat with the remaining blades page 7 blade canopy set screw canopy 10 W...

Страница 8: ...lace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Litex Industries We will r...