3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 10ft. (3.05m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to
400 square feet (37.2 square meters).
This fan can be mounted with a
downrod
on a
regular (no slope) ceiling
only
. Fan
cannot
be
mounted as a flushmount
nor
on a vaulted
ceiling.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
page 4
ON
OFF
ON
OFF
j-hook
hanging bracket
downrod
installation
12f
t.
- 20f
t.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66 m - 6.1m)
blade edge
10
feet
(3.05m)
(76cm)
30
inches
spring washers
outlet box screws
flat washers
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light
switch is turned to the OFF position.
WARNING
: Failure to disconnect power supply
prior to installation may result in serious injury.
Remove existing fixture.
WARNING
: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight
of the fan. Ensure outlet box is clearly marked
"Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to
do so can result in serious injury.
CAUTION
: Be sure outlet box is properly
grounded and that a ground (
GREEN
or bare)
wire is present.
Install hanging bracket to outlet box using
original screws, spring washers and flat
washers provided with new or original outlet
box.* Arrange electrical wiring to the front or
back side of the hanging bracket.
*Note
: It is very important that you use the
proper hardware when installing the hanging
bracket as this will support the fan.
CANNOT be
installed on
angled or
vaulted ceilings
flushmount
installation