11. Testing Your Fan.

bulb

motor
housing

female plug 

male plug 

10. Light Kit Assembly. (cont.)

Connect male plug from motor housing to female 
plug from light kit fitter, matching up the colors 
on the male plug with the colors on the female 
plug for correct fit. Be sure that the plugs connect 
completely.

Align holes in fitter plate with holes in light kit 
fitter. Re-insert screws that were previously 
removed and securely tighten all 3 screws with a 
Phillips screwdriver.

Install one 6.5 watt medium base LED bulb 
(included).

IMPORTANT

: When replacing bulb, please allow 

bulb and glass shade to cool down before 
touching.

Locate clips inside of light kit fitter and place edge 
of glass shade into clips. 

Note

: Pull down VERY GENTLY on glass shade to 

make sure that glass shade is secure. 

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and wall switch (if applicable). Test fan 
speeds with the pull chain labeled FAN. Start at 
the OFF position (no blade movement). First pull 
will set the fan to HI. Second pull will set the fan 
to MEDIUM. Third pull will set the fan to LOW. 
Fourth pull will re-set the fan to OFF setting. If 
applicable, test light with the pull chain labeled 
LIGHT. (

Refer to 

diagram 1

.

) If fan and/or light do 

(does) not function, please refer to 
"Troubleshooting" section to solve any issues 
before contacting Customer Service.

   

Turn fan completely off 

before

 moving the reverse 

switch. Set reverse switch to recirculate air 
depending on the season:
 

- LEFT position in summer (

diagram 2

)

 

- RIGHT position in winter (

diagram 3

)

A ceiling fan will allow you to raise your 
thermostat setting in summer and lower your 
thermostat setting in winter without feeling a 
difference in your comfort.

Important

: Reverse switch must be set either 

completely LEFT

 or 

completely RIGHT

 for fan to 

function. If the reverse switch is set in the 

middle

 

position (

diagram 4

), fan will not operate.

   

Attach pull chain extension(s) supplied or custom 
pull chain extension(s) (sold separately) to the 
end(s) of the pull chain(s). 

light

pull chain
extension

fan

pull chain
extension

diagram 2

diagram 3

diagram 4

diagram 1

light kit fitter

glass shade

reverse switch

Содержание AU52BNK3L

Страница 1: ...98 Table of Contents Safety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 APPROVED FOR USE IN DAMP LOCATIONS ...

Страница 2: ...d to accept only one 12 gauge house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only 6 After installation is complete check that all connections are absolutely secure 7 After...

Страница 3: ... that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball with pin and clip 1 piece d motor housing 1 piece e yoke cover 1 piece f fitter plate 1 piece g light kit fitter 1 piece h glass shade 1 piece i blade arm 3 pieces j blade 3 pieces k hardware packs g IMPORTANT REMINDER You must use the parts provided with this fan for proper i...

Страница 4: ...acket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan 3 Installation Preparation Installation requires these tools Phillips screwdriver flathead screwdriver adjustable pliers or wrench stepladder wire cutters and rated electrical tape downrod installation flushmount installation To prevent personal injury and damag...

Страница 5: ...nsert stop pin into top of extended downrod and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely WARNING Failure to tighten set screw completely could result in the fan becoming loose and possibly falling set screw hole set screw hanging ball stop pin pin clip A B Tip To prepare for threading electrical wires through downrod apply a...

Страница 6: ...ng the canopy over the hanging bracket tab Use one of the non slotted holes on the rim of the canopy to do so canopy canopy cover canopy motor housing hanging ball slot hanging bracket tab motor housing hanging bracket tab With the hanging bracket secured to the outlet box and able to support the fan you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through openin...

Страница 7: ...res together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK or RED supply from the independent switch Wrap each wire connector separately with electrical tape as an extra safety measure black black white white black supply wire white supply wire from ceiling from fan g...

Страница 8: ... may crack and break Locate 9 blade attachment screws and 9 decorative nuts in one of the hardware packs Place blade arm on TOPSIDE of blade aligning holes in blade arm with holes in blade as shown Insert 3 decorative nuts into holes in blade from UNDERSIDE of blade i e the side that will face the floor making sure to completely insert each decorative nut so that the blade arm can be attached corr...

Страница 9: ...n no blade movement First pull will set the fan to HI Second pull will set the fan to MEDIUM Third pull will set the fan to LOW Fourth pull will re set the fan to OFF setting If applicable test light with the pull chain labeled LIGHT Refer to diagram 1 If fan and or light do does not function please refer to Troubleshooting section to solve any issues before contacting Customer Service Turn fan co...

Страница 10: ... water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or exposure to salt air is specifically exempted under this warranty Neither Litex Industries nor the manufacturer will assume any liability resulting from improper installation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any oth...