3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters and rated electrical tape.
4. Hanging Bracket Installation.
page 3
ON
OFF
ON
OFF
hanging bracket
spring washers
outlet box screws
12f
t.
- 20f
t.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
blade edge
7 feet
(2.13m) (76 cm)
30
inches
flat washers
This fan can be mounted with a
downrod
on a normal or vaulted ceiling. The hanging
length can be extended by purchasing a longer
downrod (0.5in./1.27cm diameter).
After installing
hanging bracket,
c
ontinue to Section 5 on page 4
for those instructions.
This fan can mount with
flushmount
installation
only
on a normal ceiling.
After installing hanging bracket, continue to
Section 6 on page 5 for those instructions.
Vaulted ceiling
angle is not to
exceed 25 degrees.
downrod
installation
flushmount
installation
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING:
Failure to disconnect power supply prior
to installation may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box, be sure
the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION
: Be sure outlet box is grounded properly and
that a ground wire (green or bare) is present.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided
with new or original outlet box.* If installing on a
vaulted ceiling, face opening of hanging bracket
towards high point of ceiling. Arrange electrical
wiring around the back of the hanging bracket and
away from the bracket opening.
*Note
: It is very important that you use the proper
hardware when installing the hanging bracket as this
will support the fan.