3. Installation Preparation.

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7ft. (2.13m) from the floor and 30in. 
(76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 
square feet (37.2 square meters). 

Installation requires these tools:

Phillips screwdriver, flat-head screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters and rated electrical tape.

4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

hanging bracket

spring washers

outlet box screws

12f

t.

  - 20f

t.

12ft.  - 20ft.

(3.66m  - 6.1m)

(3.66m  - 6.1m)

blade edge

7 feet

(2.13m) (76 cm)

30 

inches

flat washers

This fan can be mounted with a 

downrod

on a normal or vaulted ceiling. The hanging 
length can be extended by purchasing a longer 
downrod (0.5in./1.27cm diameter). 

After installing 

hanging bracket,

 c

ontinue to Section 5 on page 4 

for those instructions. 

This fan can mount with 

flushmount

 installation 

only 

on a normal ceiling.  

After installing hanging bracket, continue to 
Section 6 on page 5 for those instructions.

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

  downrod
installation

flushmount
 installation

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position. 

WARNING: 

Failure to disconnect power supply prior 

to installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure 

the outlet box is securely attached to the building 
structure and can support the full weight of the fan. 
Ensure outlet box is clearly marked "Suitable for Fan 
Support." If not, it must be replaced with an approved 
outlet box. Failure to do so can result in serious injury.

CAUTION

: Be sure outlet box is grounded properly and 

that a ground wire (green or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers provided 
with new or original outlet box.* If installing on a 
vaulted ceiling, face opening of hanging bracket 
towards high point of ceiling. Arrange electrical 
wiring around the back of the hanging bracket and 
away from the bracket opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this 
will support the fan.

Содержание E-FR52ABZ5CR

Страница 1: ...ssembly Optional pgs 7 8 Remote Control Operation pg 9 Testing Your Fan pg 9 Troubleshooting pg 10 Warranty pg 10 Parts Replacement pg 10 net weight of fan 18 96 lb 8 6 kg E192641 READ THESE INSTRUCTI...

Страница 2: ...d wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to...

Страница 3: ...ached to light kit fitter 1 piece m hardware packs page 2 a b d e g c h f i j m l k Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofo...

Страница 4: ...instructions Vaulted ceiling angle is not to exceed 25 degrees downrod installation flushmount installation Turn off circuit breakers to current fixture from breaker panel and be sure operating light...

Страница 5: ...nrod B the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of extended downrod and raise hanging ball Be sure stop pin a...

Страница 6: ...eal 6 holes Notice that 3 of these holes are larger than the rest of them If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor hous...

Страница 7: ...is pre set and not recommended for use If your remote control interferes with other appliances change to another matching code on the remote control transmitter and receiver In order for the remote co...

Страница 8: ...te finial bulb male plug female plug switch housing and light kit fitter Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws...

Страница 9: ......

Страница 10: ...t from the light kit fitter and then gently feed the BLACK and WHITE wires from the light kit fitter through the hole in the middle of the switch housing Locate cap in one of the hardware packs and pl...

Страница 11: ...function with remote control Test dimmer function by holding down the LIGHT button for more than 2 seconds If the remote control operates all of the functions of the fan and light battery has been in...

Страница 12: ......

Страница 13: ...ly 3 Check to be sure set screw on hanging ball is tightened securely Warranty LITEX LIFETIME LIMITED WARRANTY LITEX INDUSTRIES LTD warrants this fan to the original household purchaser for indoor use...

Страница 14: ......