LC
D
M
od
ule
PR-880 /
BM5A /
BM7
Module Driving Equipment
measuring distance
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25
℃
(Room Temperature):
Item
Unit
Conditions
Min.
Typ.
Max.
Note
Horizontal (Right)
CR = 10 (Left)
TBD
65
65
-
Vertical (Up)
CR = 10 (Down)
TBD
65
55
keep total
120(Mayb
e 60,60)
Horizontal (Right)
CR = 5 (Left)
TBD
TBD
Viewing Angle
[degree]
Vertical (Up)
CR = 5 (Down)
TBD
TBD
Contrast ratio
Normal Direction
TBD
500
-
Rising Time
-
TBD
TBD
Falling Time
-
TBD
TBD
Response Time
[msec]
Falling
-
12
Note 1
Red x
0.61
0.64
0.67
Red y
0.30
0.33
0.36
Green x
0.27
0.30
0.33
Green y
0.56
0.59
0.62
Blue x
0.12
0.15
0.18
Color / Chromaticity
Coordinates (CIE)
Blue y
0.07
0.10
0.13
White x
0.28
0.31
0.34
Color Coordinates (CIE)
White
White y
0.30
0.33
0.36
White Luminance @ CCFL
5.6mA (center)
[cd/m
2
]
1600
-
Luminance Uniformity
[%]
75
80
Note 2
Crosstalk (in 75Hz)
[%]
1.2
1.5
Note 3
Flicker
dB
-20
Note 4
Equipment Pattern Generator, Power Supply, Digital Voltmeter, Luminance meter (PR 880, BM-5A ,
BM 7 ,CS-1000, CA210, SR_3 & EZ Contrast(ELDIM)* )
Aperture
1
∘
with 50cm viewing distance
Test Point Center (VESA point 9)
Environment < 1 lux
*
’
EZ Contrast is different measurement tool with very close viewing distance.