8.0 Reliability
Reliability test condition
No Test Item
Test Condition
1 Temperature Humidity Bias (THB)
50
℃
, 80%, 300hours
2 High Temperature Operation (HTO)
50
℃
, 300hours
3 Low Temperature Operation (LTO)
0
℃
, 300hours
4 High Temperature Storage (HTS)
60
℃
, 300hours
5 Low Temperature Storage (LTS)
-20
℃
, 300hours
6 Thermal Shock Test (TST)
-20
℃
/30min, 60
℃
/30min, 100 cycles
7 On/Off Test
On/10sec, Off/10sec, 30,000 cycles
8 Shock Test (Non-Operating)
50G, 20ms, Half-sine wave (+ X, +Y, +Z)
9 Vibration Test (Non-Operating)
1.5G(10~200Hz P- P), 30 Minutes each Axis (X, Y, Z)
10 ESD (ElectroStatic Discharge)
Contact Discharge:
±
8KV, 150pF(330
Ω
) 1sec, 8 points, 25 times/ point
Air Discharge:
±
15KV, 150pF(330
Ω
) 1sec, 8 points, 25 times/ point
11 Altitude Test
Operation:10,000 ft
Non-Operation:30,000 ft
12 Drop Test
The drop height is 60cm