LITE-CHECK INSPECTOR 920
Page: 11 of 36
Graphic
Panel
Button
Remote
Button
Function
RIGHT
RIGHT
Operates right turn circuit
ABS
BACK
ABS
BACK
ABS Test – Initiates the ABS test routine (30
to 45 seconds). Pressing the ABS (BACK)
button at other times will display the
previous screen.
SELECT
*
HELP
SELECT*
HELP
ABS select – Enter on selected option, or
view on screen
DOWN
DOWN
Move display cursor down
UP
UP
Move display cursor up
AUTO
CIRCUIT
TEST
N/A
No longer supported
ALARM
MUTE
N/A
Turns alarm off during electrical test
TRACTOR
OUTPUT/
CABLE
TEST
N/A
Tractor output test /Cable Test
*
SELECT details:
Diagnostic testers such as the INSPECTOR 920 and other
members of the LITE-CHECK family of automatic testers activate a
single circuit at a time and monitor the activity on all of the circuits
to provide computer assisted fault identification. Multiple circuits
can be activated at the same time by using the “SELECT” button on
the tester or the remote control unit. In this mode, multiple circuits
can be switched on and off, with the tester’s computer display
indicating the total current draw of all of the circuits. Press the
“SELECT” button to leave this mode.
Equipment and Setup
The LITE-CHECK Inspector 920 diagnostic tester is designed for easy operation and
setup. Some additional items are required to fully utilize all of the 920’s functions.