Problem
Possible Cause (s)
Corrective Action
Zero output
from
receptacles
1. Engine speed is too slow
2. Open or shorted wiring
1. Faulty capacitor
2. Open/shorted rotor or stator windings
3. Open rectifier
1. Adjust engine speed
2. Clean and reconnect all wiring
3. Replace capacitor
4. Test winding resistance, replace winding
if necessary
5. Test rectifier replace if necessary
Low output
voltage with
no load
1. Engine speed is too slow
2. Open rectifier
3. Faulty capacitor
4. Open/shorted rotor or stator windings
5. Alternator not magnetized
1. Adjust engine speed
2. Test rectifier, replace if necessary
3. Replace capacitor
4. Test winding resistance, replace winding
if necessary
5. Re-magnetize the alternator
High output
voltage with
no load
1. Faulty capacitor
2. Engine speed is too fast
1. Replace capacitor
2. Adjust engine speed
Low output
voltage
under
load
1. Open rectifier
2. Engine speed too low at full load
3. Excessive load applied
1. Test rectifier, replace if necessary
2. Adjust engine speed
3. Reduce the applied load
Erratic
output
voltage
1. Dirty, corroded, or loose wiring
connection
2. Unbalanced load applied
1. Referring to the wiring diagram, clean
and reconnect all wiring
2. Remove all loads, then apply each one
individually to determine which one is
causing erratic function
Noisy
operation
1. Loose generator or engine bolt
2. Short circuit in generator field or load
3. Faulty bearing
1. Tighten all mountings
2. Test winding resistance, replace field
winding if necessary Test load devices
for shorts. Replace defective load device
3. Replace bearing
Engine
won’t start
1. No fuel
2. Fuel switch is in closed position
3. Engine switch is in closed position
4. Spark plug dirty or wrong gap
5. No enough compression inside the
cylinder
6. battery discharged
1. Check fuel
2. Place fuel switch in open position
3. Place engine switch in open position
4. Clean spark plug. Adjust gap, replace if
necessary.
5. Check leakage from the cylinder
6. Recharge the battery
tRoUbLeshootING GUIde
Содержание LPP Series
Страница 1: ...LPP petrol genset Operators Handbook ORIGINAL INSTRUCTIONS P027 10760 LPP SERIES ...
Страница 35: ...35 LPP PETROL GENSET operators handbook 1 2 1 3 2 5 7 1 2 2 2 7 PARTS LIST yf168fd 2 ...
Страница 40: ...40 LPP PETROL GENSET operators handbook ZHEJIANG YAOFENG POWER TECHNOLOGY CO LTD Model YF190FD 2 yf190fd 2 ...
Страница 45: ...45 LPP PETROL GENSET operators handbook ZHEJIANG YAOFENG POWER TECHNOLOGY CO LTD Model YF192FD yf192fd ...
Страница 50: ...50 ...
Страница 51: ...51 ...