ALPHA series engines worksHoP mAnuAL
64
it to the ‘Start’ position.
4. For ambient starting temperatures below -10°C
(14°F) turn the key clockwise to the ‘Preheat’
position for 15 to 20 seconds before turning the
key to the ‘Start’ position.
5. Immediately the engine starts the key must be
turned anti clockwise and held in the 'Preheat’
position until the engine has attained full speed.
6. When the engine has attained full speed the
key must be moved anti clockwise to the ‘Run’
position.
7. On variable speed engines reduce the speed as
necessary.
4.1.6 stopping the industrial engine
These are only applicable to engines with key
start.
1. If possible remove the load from the engine.
2. If a variable speed control is fitted reduce the
engine speed.
3. On engines fitted with a fuel control solenoid turn
the key to the ‘STOP’ position.
Figure 4.1.5 Key Start
4. On non-automatic engines move the engine
control lever anti-clockwise into the stop position
and turn the key to the ‘STOP’ position.
CAution
Turning the key to the ‘STOP’ position alone
will not stop the engine unless a fuel control
solenoid is fitted.
Figure 4.1.6 Stopping
4.1.7 Preliminary instructions
wArning
Starting any engine can be dangerous in
the hands of inexperienced people. Before
attempting to start any engine the operator
should read the “Safety Precautions" and be
conversant with the use of the engine controls
and the correct starting procedures.
wArning
EXHAUST GASSES CONTAIN CARBON MONOXIDE
WHICH IS A COLOURLESS, ODOURLESS
AND POISONOUS GAS THAT CAN CAUSE
UNCONSCIOUSNESS AND DEATH.
4.1.8 starting
wArning
IF THE ENGINE FAILS TO START WITHIN 30
SECONDS, RELEASE THE kEY AND ATTEMPT
TO RESTART AFTER ALLOWING SUFFICIENT
TIME FOR ALL MOVING PARTS TO STOP.
FAILURE TO OBSERVE THIS MAY RESULT IN AN
EXPLOSIVE MIX IN THE EXHAUST SYSTEM.
1. Press and hold the low oil pressure switch
bypass button during engine cranking and until
the engine attains full speed.
2. Turn the key clockwise to the ‘START’ position
and release it immediately the engine tarts.
4.1.9 stopping the engine
1. If possible remove the load from the engine.
2. Turn the key to the ‘STOP’ position.
Содержание 0600123LPW3A01
Страница 1: ...LPW LPWS TURBO ENGINES WORKSHOP MANUAL ALPHA SERIES P027 08240 ...
Страница 87: ...87 ...